11.1.6
Connecting the power cables
Required tools:
● Torx screwdriver T25 for protective conductor connection (Torx slot)
● Flat-bladed screwdriver size 4 for power cables
● Flat-bladed screwdriver for hose clamp
Table 11- 8
Connecting power cables for a 100 mm wide component using internal air cooling as an example
Attach the protective
conductor (PE)
Tightening torque: 3 Nm
Required tools:
● Torx screwdriver T25 for protective conductor connection (Torx slot)
● (Torque) wrench M8 for power cables
● Flat-bladed screwdriver for hose clamp
Table 11- 9
Connecting power cables for a 200 mm wide component using internal air cooling as an example
Release and open the cover of the
terminal strip.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
11.1 Shield connecting plates for power supply and motor cables
Attach the power cable.
Tightening torque: 1.8 Nm
Remove the M8 screws.
Tighten the hose clamp at
the shield connecting plate.
Attach the protective conductor and the
power cable.
Tightening torque: 13 Nm
Accessories
The power cable is
connected.
643