Cable Connection And Shield Support - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Accessories
11.5 DC link adapter
11.5.6.3

Cable connection and shield support

In order to simplify installing the DC link connecting cables at the DC link adapter, first fix the
cables to the control cabinet panel (see above).
Required tools:
● Size 6 Allen key to attach the cables
● Suitable tool for hose clamps, e.g. flat-bladed screwdriver
Table 11- 24 Connecting the DC link connecting cables to the DC link adapter
1. Fix the first conductor of the DC link connecting
cable to the profile rail using a cable clamp.
3. Slide the cable clamp onto the tongue, and
then insert the end of the cable into the DCN
connection of the DC link adapter.
650
2. Route the cable end through an appropriate
cable clamp.
4. Tighten the cable using an Allen key.
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8