Release and withdraw the connector (1).
Release the catch (2) and remove the fan.
Table 14- 2
Installing a fan
Size 50 mm
Before installing the fan, please note the airflow direction. The arrow on the fan must point toward the cooling ribs.
Push the fan into a position where it is completely latched.
Caution: Do not crush the connecting cables!
Insert the connector until it latches into place.
Attach the fan cover.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Size 100 mm
Service and Support Booksize
Sizes 150 mm and 200 mm
14.2 Replacing the fan