Connection Of The 24 V Busbars - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Figure 12-17 DC-link busbar connection using a reinforced DC-link busbar at a 50/100 mm module
12.6.2

Connection of the 24 V busbars

Connection of the 24 V busbars
The 24 V busbars of the components are connected using the red 24 V connectors in the
accessories pack. A 24 V connector must be plugged onto the 24 V busbars between the
Line Module, Motor Module and DC-link component. The 24 V connectors must be attached
before the drive line-up is commissioned!
Working steps:
● Place the 24 V connectors on to the 24 V busbars.
● Press the 24 V connectors down until they click into place.
● If required, mount the 24 V terminal adapter to supply the 24 VDC.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Standard DC-link busbar (6 mm)
Reinforced DC-link busbar (8 mm)
Connecting the DC-link busbar to the module using a M4x20 screw
DC-link bridge
Cabinet design and EMC Booksize
12.6 Electrical connection
713

Advertisement

Table of Contents
loading

Table of Contents