Siemens Sinamics S120 Manual page 714

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Cabinet design and EMC Booksize
12.6 Electrical connection
Fire hazard for 24 V connectors and unconnected DC-link busbars
The red 24 V connectors may only be used when the DC-link busbars of the components
are also connected. Otherwise the 24 V connectors can burn and cause severe injury or
death as result of fire or smoke.
• If the DC-link busbars of the components are not connected, each component must be
Danger to life due to electric shock when connecting and disconnecting 24 V connections in
operation
When opening plug connections in operation, arcs can result in severe injury or death.
• Only withdraw or insert the 24 V connectors in a no-voltage state.
714
Mounted 24 V terminal adapter (Torx T10, tightening torque 0.5 Nm)
Mounted 24 V connector
WARNING
supplied with 24 V separately via a 24 V terminal adapter.
WARNING
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6

Advertisement

Table of Contents
loading

Table of Contents