Replacing the fan for components, size 300 mm
Installing the fan module on 300 mm wide components is described in Chapter "Installation"
of the respective component. The fan module is removed in the inverse sequence to
installing.
14.2.3

Replacing the fan on an Active Interface Module

Table 14- 4
Replacing the fan in an Active Interface Module, 16 kW
Open the fan cover. To do this, release the combination
screws
M5 (3 Nm).
Push out the 8 expansion rivets.
Fix the fan with 8 new expansion rivets.
To install, carry out the above steps in reverse order. The torques must be carefully
observed.
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Open the fan cover and release the connector.
Remove the fan.
Service and Support Booksize
14.2 Replacing the fan