X1/X2 Motor Connection; X11/X12 Motor Brake Connection - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Motor Modules Booksize Compact
7.3 Interface description
7.3.2

X1/X2 motor connection

Table 7- 1
X1/X2 motor connection
For ring cable lugs without insulation
1)
7.3.3

X11/X12 motor brake connection

Table 7- 2
X11/X12 motor brake connection
Terminals
+ (BR+)
- (BR-)
The circuit for protecting the brake against overvoltage is integrated in the Motor Module and does not need to be
1)
installed externally. The max. load current is 2 A, the min. load current 0.1 A.
494
Terminal
U2
V2
W2
PE connection
Technical data
Brake connector
Voltage 24 V DC
Max. load current 2 A
Min. load current 0.1 A
Max. connectable cross-section 2.5 mm
Type: Spring-loaded terminal 2 (Page 754)
Manufacturer: Wago; order number: 721-102/026-000/56-000
The brake connector is part of the scope of delivery.
Technical data
Type: Screw terminal 5 (Page 755)
Max. cross-section that can be connected: 6 mm
Tightening torque: 1.2 ... 1.5 Nm
Single Motor Modules 3 ... 18 A
Threaded hole M5 / 3 Nm
Double Motor Modules 1.7 ... 5 A
Threaded hole M5 / 3 Nm
:
1)
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6