Technical Data - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Line Modules Booksize
4.9 Smart Line Modules with external air cooling
Note
If the cooling air requirement is not covered by the filtered fan, the components cannot
output their specified power.
The filters with filter fan must be regularly checked for dirt and cleaned if necessary.
Help with the mechanical control cabinet design is available from:
Siemens AG
Industry Sector, IA DT MC MF - WKC AS
TCCCC (Technical Competence Center Cabinets Chemnitz)
Postfach 1124
09070 Chemnitz, Germany
E-mail: cc.cabinetcooling.aud@siemens.com
4.9.8

Technical data

Table 4- 85
Technical data Smart Line Modules Booksize external air cooling
Internal air cooling
Rated power
Infeed
Rated power (S1)
1)
S6 operation (40 %)
1)
Peak infeed power
1)
Regenerative feedback
Continuous regenerative
power
Peak regenerative power
Supply voltages
Line voltage
Line frequency
Electronics power supply
DC link voltage
Overvoltage trip
Undervoltage trip
2)
Input currents
Rated input current
at AC 400 V
at AC 380 V / AC 480 V
S6 (40 %)
at AC 400 V
Peak current
at AC 400 V
324
6SL3131– 6AE15–0AAx
kW
5
kW (P
)
5
n
kW (P
)
6,5
s6
kW (P
)
10
max
kW
5
kW
10
V
3 AC 380 ... 480 ± 10 % (-15 % < 1 min)
AC
Hz
47 ... 63
V
24 (20.4 ... 28.8)
DC
V
510 ... 720
DC
V
820 ± 2 %
DC
V
360 ± 2 %
DC
A
8,1
AC
A
8,6 / 6,7
AC
A
10,6
AC
A
15,7
AC
6AE21–0AAx
6TE21-6AAx
10
16
10
16
13
21
20
35
10
16
20
35
16,2
27,5
17 / 12,8
29 / 24,5
21,1
35
31,2
57,5
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
6TE23-6AAx
6TE25-5AAx
36
55
36
55
47
71
70
91
36
55
70
91
59
90
62 / 51
94 / 77
76
106
112
130