Disturbance of the 2 x 9 A Double Motor Module with 300% overload during operation on a
16 kW Line Module
The maximum output of a 16 kW Line Module is not sufficient for the operation of a 2 x 9 A
Double Motor Module with 300% overload.
• Do NOT operate the 2 x 9 A Double Motor Module with 300% overload on a 16 kW Line
• Use at least a 36 kW Active Line Module or Smart Line Module for operation with 300%
• Only operate a 2 x 9 A Double Motor Module on a 16 kW Line Module when the
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Module.
overload.
maximum current is limited to 2 x I