Motor Modules Booksize
6.2 Motor Modules with internal air cooling
Note
Disturbance of the 18 A Single Motor Module with 300% overload during operation on a
16 kW Line Module
The maximum output of a 16 kW Line Module is not sufficient for the operation of an 18 A
Single Motor Module with 300% overload.
• Do NOT operate the 18 A Single Motor Module with 300% overload on a 16 kW Line
Module.
• Use at least a 36 kW Active Line Module or Smart Line Module for operation with 300%
overload.
• Only operate an 18 A Single Motor Module on a 16 kW Line Module when the maximum
current is limited to 2 x I