Meaning Of Leds; Smart Line Modules 5 Kw And 10 Kw - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Line Modules Booksize
4.8 Smart Line Modules with internal air cooling
4.8.5

Meaning of LEDs

4.8.5.1

Smart Line Modules 5 kW and 10 kW

Table 4- 71
Meaning of the LEDs on 5 kW and 10 kW Smart Line Modules
LED
Color
RDY
Off
Green
Continuous
light
Yellow
Continuous
light
Red
Continuous
light
DC LINK
Off
Yellow
Continuous
light
Red
Continuous
light
Danger of death when live parts of the DC link are touched
Irrespective of the state of the LED "DC LINK", hazardous DC link voltages can be present.
This means the touching of live parts can result in death or serious injury.
• Observe the warning information on the component.
288
Status
The electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation.
The precharging has not yet been completed.
The bypass relay has dropped out.
The EP terminals are not supplied with 24 V DC.
Overtemperature
overcurrent
The electronics power supply is missing or outside the
permissible tolerance range.
The DC link voltage is within permissible tolerance
range.
The DC link voltage is outside the permissible tolerance
range or a line fault is present.
WARNING
Description, cause
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Remedy
Diagnose the fault (using
the output terminals) and
acknowledge (using the
input terminal).
Check the line supply
voltage.
Booksize Power Units