Connecting Power Cables (Using The Vpm 200 Dynamik As An Example) - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

10.2.7.2

Connecting power cables (using the VPM 200 Dynamik as an example)

Figure 10-16 Connection points of the Voltage Protection Module VPM200 Dynamic
Table 10- 13 Short designations
Short designation
VS1, VS2
VS3, VS4
K1, K2
K3, K4
U
, U
1
U
, U
3
V
, V
1
W
1
W
3
PE
U
V
W
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
Explanation
Cable screwed joint 1 or 2 in the housing entry of the VPM, towards Motor
Module
Cable screwed joint 3 or 4 in the housing entry of the VPM, towards motor
Cable 1 or 2 to the Motor Module
Cable 3 or 4 to the motor
Connection bolts on busbar U
2
Connection bolts on busbar U
4
Connection bolts on busbar V
2
, W
Connection bolts on busbar W
2
, W
Connection bolts on busbar W
4
, PE
, PE
, PE
Connection bolts on busbar PE
1
2
3
4
Busbar U in the VPM
Busbar V in the VPM
Busbar W in the VPM
Motor-side power components
10.2 Voltage Protection Module VPM
613