X200-X202 Drive-Cliq Interface; Connection Example - Siemens Sinamics S120 Manual

Booksize power units
Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

6.5.2.4

X200-X202 DRIVE-CLiQ interface

Table 6- 50
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking cover (50 pcs.) Order number: 6SL3066-4CA00-0AA0
6.5.3

Connection example

Figure 6-103 Connection example for Motor Module Liquid Cooled (200 A)
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6
X200-X202: DRIVE-CLiQ interfaces
Pin
Name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground