X200-X202 Drive-Cliq Interface - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Danger to life due to electric shock in the event of voltage flashovers at the temperature
sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Use temperature sensors that comply with the specifications relating to protective
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
6.5.2.4

X200-X202 DRIVE-CLiQ interface

Table 6- 50
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking cover (50 pcs.) Article number: 6SL3066-4CA00-0AA0
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
WARNING
separation.
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal
Module TM120.
X200-X202: DRIVE-CLiQ interfaces
Pin
1
2
3
4
5
6
7
8
A
B
Name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Motor Modules Booksize
6.5 Motor Modules Liquid Cooled
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground
449

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents