Smart Line Modules
5.6 Interface description
5.6.5

X24 24 V terminal adapter

Table 5-4
X24: 24 V terminal
adapter
Connectable cable cross-sec‐
tions
Stripped length
Tool
Tightening torque
The 24 V terminal adapter is included in the scope of supply.
5.6.6

Meaning of the LEDs

The Smart Line Module has 3 LEDs on the front cover. The upper LED (RDY 1) and the lower LED
(DC LINK) are active.
Table 5-5
Meaning of the LEDs on the Smart Line Module
Status
LED RDY 1
DC LINK
Off
Off
Green
--
1)
Orange
Red
Orange
Orange
Red
--
1)
Green/red
--
1)
(0.5 Hz)
62
X24: 24 V terminal adapter
Termi‐
Function
nal
+
24 V power supply
M
Ground
Flexible
with end sleeve, without plastic sleeve
with end sleeve, with plastic sleeve
AWG / kcmil
12 mm (0.47 inch)
Screwdriver 1.0 x 4.0 mm
1.2 ... 1.5 Nm (10.6 ... 13.3 lbf in)
Description, cause
The electronics power supply is missing or outside the
permissible tolerance range.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
The DC link voltage is present.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place. The DC link voltage is out‐
side the permissible tolerance range.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Firmware is being downloaded.
Technical specifications
24 V DC supply voltage
Electronics ground
0.5 ... 6 mm
0.5 ... 6 mm
0.5 ... 6 mm
20 ... 8
Check the line voltage.
Resolve and acknowledge the
fault.
Equipment Manual, 01/2022, 6SL3097-6AC30-0BP0