Dell PowerConnect J-EX4200-24T Software Manual page 618

J series; j-ex series
Table of Contents

Advertisement

Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS
Table 77: Chassis Alarms for J-EX8200 Switches (continued)
Power supply
A power supply slot
that contained a power
supply at bootup is
now empty.
Power supply
A power supply has
failed due to an input
or output failure, or due
to temperature issues.
Power supply
A power supply's
internal connection to
the switch is not
operating properly.
Temperature
The chassis warm
temperature threshold
has been exceeded
and fan speeds have
increased.
546
Install a power supply
Yellow
in the empty power
supply slot.
Replace the failed
Red
power supply.
Remove and reinsert
Red
the power supply.
If removing and
reinserting the power
supply does not resolve
the problem, reboot
the switch.
Adjust room
Yellow
temperature
downward, if possible.
Ensure airflow through
the switch is
unobstructed.
You can ignore this alarm in cases
in which a power supply slot can
remain empty.
You will not see this alarm if the
switch is booted with an empty
power supply slot.
This alarm is expected during
power supply removal and
installation.
This alarm can be triggered by a
line card insertion. The alarm
condition corrects itself when
seen for this reason.
The chassis is warm and should
be cooled down. The switch is still
functioning normally.
To monitor temperature:
user@switch>
show chassis
environment
To monitor temperature
thresholds:
user@switch>
show chassis
temperature-thresholds