Omron CJ1W-SCU32 Operation Manual page 457

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

Setting Example
When password is OMRON-CO.
0006
0008
Password Verification Operation
The number of retries is 3 for password verification.
Password verification
(starting #552)
character string
(Retry up to 3 times)
NG
Data Send/Receive (Sequence No. 553 (Hex 0229))
Data Send/Receive can be executed using sequence No. 553. The send data sent to another exchange
is set in the words specified by the 3rd operand of PMCR(260). Data received by the PLC is stored in
the words specified by the 4th operand of PMCR(260).
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
4F4D
524F
4E2D
434F
O M
R O
N –
Character string length of password sent to modem (bytes)
Code length of PMCR(260) when it is used (words)
PLC
Dispatching
"Password: "
Password
Receiving
password
Verifying
password
When Protocol Macro Execution Flag turns ON:
Verification
result
Port 1: CIO 190915 for the Serial Communica-
tions Board and CIO 1500 + 25 x unit number
+9, bit 15 for Serial Communications Units.
OK
Port 2: CIO 191915 for the Serial Communica-
Terminating
tions Board and CIO 1500 + 25 x unit number
process
+19, bit 15 for Serial Communications Units.
C O
Personal computer
(remote exchange)
Receiving character
string
Issuing password
A Standard System Protocol
R-123