Device Memory Fill as Word Data (T/C Device Type)
(Sequence No. 805 (Hex 0325)) (Command Code: WW)
This sequence writes the word (PV) data starting from the specified word + 6 in the CS/CJ-series CPU
Unit to the number of device points starting from the specified device address for the specified device
type (T, C) in the Mitsubishi Computer Link Module with the specified station number (and the PLC
number that follows).
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Offset
+0
Number of send data words (4 digits hex)
+1
Station No.
(2 digits hex)
+2
Device type (4 digits hex)
+3
(Unde-
fined)
+4
(Undefined)
+5
Number of send data bytes (4 digits hex)
+6
Write data (4 digits hex)
on
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Offset
+0
Number of receive data words
+1
Station No.
(2 digits hex)
+2
Error code
(2 digits hex)
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Number of send data words
+0
+1
Station No.
PLC No.
+2
Device type
+3
Device No.
(Undefined)
+4
(Undefined)
Device points
+5
Number of send data bytes
+6
Write data
on
Contents (data format)
PLC No.
(2 digits hex)
Device No. (3 digits hex)
Device points
(2 digits hex)
Number of receive data words
+0
Station No.
PLC No.
+1
+2
Error code
(Undefined)
Contents (data format)
PLC No.
(2 digits hex)
(Undefined)
A Standard System Protocol
Data
0007 to 00FA hex (7 to 250 decimal)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
Set the device type (2 characters) in ASCII.
Set the first write address of the write data.
Set the device points to write.
Specify the number of text data bytes for the com-
munications line (i.e., twice the number of text
bytes in S+6 onwards)
Set the write data.
Data
0002 or 0003 hex (2 or 3 decimal)
Station No.: 00 to FF hex
PLC No.: 00 to FF hex
Stores the error code converted to hexadecimal.
No error code is stored for normal completion.
R-51