Omron CJ1W-SCU32 Operation Manual page 437

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

AVG Move (H) Times Set (3000-series, High-speed Type)
(Sequence No. 425 (Hex 01A9))
This sequence uses the average move and high-speed data output as the averaging method and sets
the averaging times per measurement interval 4.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Offset
+0
Number of send data words (4 digits Hex)
+1
Number of averaging times (4 digits BCD)
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not
turned ON.
AVG Move (L) Times Set (3000-series, High-speed Type)
(Sequence No. 426 (Hex 01AA))
This sequence uses the average move and low-speed data output as the averaging method and sets
the averaging times per measurement interval 4.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Offset
+0
Number of send data words (4 digits Hex)
+1
Number of averaging times (4 digits BCD)
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
• This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not
turned ON.
• This sequence will be processed the same as sequence No. 425 AVG move (H) times set for
5000-series Laser Micrometers.
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
+0
Number of send data words
+1
Number of averaging times
Contents (data format)
+0
Number of send data words
Number of averaging times
+1
Contents (data format)
A Standard System Protocol
Data
0002 (fixed)
16 to 2048
(32 to 2048 for 5000/6000 Series)
Data
0002 (fixed)
32 to 2048
R-103