Omron CJ1W-SCU32 Operation Manual page 364

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

A Standard System Protocol
Variable Area Fill
(Sequence No. 613 (Hex 0265))
This sequence writes the same data from the address of the specified variable type to the specified
node number.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of
send data
Offset
+0
Number of send data words
+1
(Undefined)
+2
Variable type
(2 digits hex)
+3
First write address (6 digits BCD)
+4
Number of elements (4 digits BCD)
+5
Number of bytes to write (4 digits hex)
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Offset
+0
Number of receive data words
+1
Response code (4 digits hex)
R-30
Number of send data words
+0
+1
(Undefined)
Node No.
+2
Variable type
+3
First write address
Number of elements
+4
+5
Number of bytes to write
Contents (data format)
Node No.
(2 digits BCD)
+0
Number of receive data words
+1
Response code
Contents (data format)
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Data
Always 0006 hex (6 decimal)
00 to 99
Set the area type (2 digits) and the first write address (6
digits). The leftmost byte of the first write address speci-
fies the address and the rightmost byte specifies the bit
location. Set the rightmost byte to 00 when bit access is
not required.
Set the number of elements to write.
Set the write data.
Always 0002 hex (2 decimal)
The CompoWay/F command response code is
stored in hexadecimal code.
Data