Omron CJ1W-SCU32 Operation Manual page 405

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

BCR Function Read (V500) (Sequence No. 355 (Hex 0163))
This sequence reads the settings of functions in the Bar Code Reader.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
Receive data
storage words
Offset
+0
Number of receive data words
(4 digits Hex)
+1
Operation mode
(ASCII 1 character)
In-zone control
(ASCII 1 character)
+2
Bar code type
(ASCII 1 character)
+3
Number of digits
(2 digits BCD)
+4
Modulus check
(ASCII 1 character)
+5
Number of matches
(1 digit BCD)
Multistep labels
(1 digit BCD)
+6
Buzzer
(ASCII 1 character)
Horizontal control mode (ASCII 1
character)
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Number of receive data words
+0
Operation mode
+1
In-zone control
+2
Bar code type
(Undefined)
Number of digits
+3
Modulus check
+4
Number of
(Undefined)
+5
matches.
+6
Buzzer
Horizontal control
Contents (data format)
A Standard System Protocol
(Undefined)
(Undefined)
Multistep
labels.
0007 (fixed)
41 ('A'):
ONLINE
42 ('B'):
ONLINE CONTROL
41 ('A'):
ON
42 ('B'):
OFF
41 ('A'):
JAN
42 ('B'):
NW7 NORMAL
43 ('C'): NW7 SMALL
44 ('D'): NW7 HEX
45 ('E'):
CODE39 NORMAL
46 ('F'):
CODE39 ST/SP Output
47 ('G'): 2 of 5 (ITF)
48 ('H'): CODE128
49 ('I'):
CODE93
4A ('J'):
2 of 5 (3BAR)
4B ('K'): 2 of 5 (5BAR)
00 to 32
41 ('A'):
No-check
42 ('B'):
Modulus 10 (all bar codes)
43 ('C'): Modulus 11 (except JAN)
44 ('D'): Modulus 16 (NW7 only)
45 ('E'):
Modulus 43 (CODE39 only)
46 ('F'):
Modulus 47 (CODE93 only)
47 ('G'): Modulus 103 (CODE128 only)
1 to 5
1 to 4
41 ('A'):
ON for normal read
42 ('B'):
ON for no-read
43 ('C'): OFF
41 ('A'):
Normal (continuous rotating)
42 ('B'):
In-zone startup
Data
R-71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-scu22Cj1w-scu42

Table of Contents