A Standard System Protocol
Additional Information
• Use sequences No. 446 (High calibration set) and No. 447 (Low calibration set) to calibrate the
Laser Micrometer. If this sequence (No. 404) is used, both the high and low calibration gauges
must be set, and the high calibration and low calibration gauges cannot be exchanged.
• The HC gauge dimension and LC gauge dimension must be set with 3 digits for the integer
portion and 4 digits for the decimal portion.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Calibration Release (Sequence No. 405 (Hex 0195))
This sequence releases the calibration of the Laser Micrometer.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
In this sequence, you cannot separately release both high and low calibration.
Program Number Set (3000-series) (Sequence No. 406 (Hex 0196))
This sequence switches the program number to a specified number.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Offset
+0
Number of send data words (4 digits Hex)
+1
Program number (1 digit BCD)
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
Retry processing is not performed for this sequence.
R-88
+0
Number of send data words
+1
(Undefined)
Contents (data format)
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Program number (1 digit BCD)
Data
0002 (fixed)
0 to 9