Omron CJ1W-SCU32 Operation Manual page 431

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

Measurement Termination (3000-series) (Sequence No. 414 (Hex
019E))
This sequence terminates a continuous measurement.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
For continuous measurement: Not available
For Zero Run Measurement:
The receive data word allocation is similar to that of sequence No. 410 (Single Run Measurement
Start).
Additional Information
This sequence may be aborted if it is executed during continuous measurements. Measure-
ments will be terminated even if the sequence is aborted. This occurs because this sequence
was executed while the Laser Micrometer was sending measurement results. The chances that
the sequence will be aborted are higher if the scheduled data output value is set to a lower value.
Data Request (3000-series) (Sequence No. 415 (Hex 019F))
This sequence requests display data in the idle measurement status or the latch data generated by the
measurement command.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
The receive data word allocation is similar to that of sequence No. 410 (Single Run Measurement
Start).
Statistic Processing Execution (3000-series) (Sequence No. 416
(Hex 01A0))
This sequence lights the statistic processing LED and implements the statistic processing.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Statistic Processing Non-execution (3000-series) (Sequence No. 417
(Hex 01A1))
This sequence turns the statistic processing LED off and does not carry out the statistic processing.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
A Standard System Protocol
R-97

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-scu22Cj1w-scu42

Table of Contents