A Standard System Protocol
Simple AVG Times Set (3000-series, High-speed Type)
(Sequence No. 423 (Hex 01A7))
This sequence uses the simple average as the averaging method and sets the averaging times per
measurement interval 4.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Offset
+0
Number of send data words (4 digits Hex)
+1
Number of averaging times (4 digits BCD)
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not
turned ON.
AVG Move Interval Set (3000-series, High-speed Type)
(Sequence No. 424 (Hex 01A8))
This sequence uses the average move as the averaging method and sets the measurement interval
number.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
Offset
+0
Number of send data words (4 digits Hex)
+1
Measurement interval number (1 digit BCD)
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Additional Information
This sequence cannot be used when DIP switch SW3, pin 5 of the Laser Micrometer is not
turned ON.
R-102
+0
Number of send data words
+1
Number of averaging times
Contents (data format)
Number of send data words
+0
+1
(Undefined)
Contents (data format)
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Data
0002 (fixed)
1 to 2048
Measurement interval number
Data
0002 (fixed)
1 to 4