Measurement Condition Set (3000-series) (Sequence No. 407 (Hex
0197))
This sequence sets measurement conditions. Conditions to be set can be selected by setting Yes/No
flags.
Send Data Word Allocation (3rd Operand of PMCR(260))
First word of send
data
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
+0
Number of send data words
+1
(Unused)
+2
+3
+4
+5
(Undefined)
+6
Decimal portion
+7
(Undefined)
Integer portion
+8
Sign
Decimal portion
+9
(Undefined)
Integer portion
+10
Sign
+11
+12
Decimal portion
+13
(Undefined)
Integer portion
+14
Sign
+15
Decimal portion
+16
(Undefined)
Integer portion
+17
Sign
+18
Decimal portion
+19
(Undefined)
Integer portion
+20
Sign
+21
Decimal portion
(Undefined)
Integer portion
+22
+23
Sign
+24
Decimal portion
+25
(Undefined)
Integer portion
+26
Sign
+27
Decimal portion
+28
(Undefined)
Integer portion
+29
Sign
A Standard System Protocol
Segment number (SG)
Measurement interval number (M)
Lower limit value (LL)
(Undefined)
Upper limit value (LH)
(Undefined)
Multistep selection limit value (L1)
(Undefined)
Multistep selection limit value (L2)
(Undefined)
Multistep selection limit value (L3)
(Undefined)
Multistep selection limit value (L4)
(Undefined)
Multistep selection limit value (L5)
(Undefined)
Multistep selection limit value (L6)
(Undefined)
R-89