With full-duplex mode, the reception buffer is cleared immediately before the sequence is executed.
While Recv and Send commands are executed, data is input into the reception buffer and is used as
the protocol macro data.
Transmission
Time reception
mode
buffer cleared
Half-duplex
Immediately before
communications
sequence execution
and immediately
after Send comple-
tion by the Send or
Send&Recv com-
mand
Full-duplex
Immediately before
(*1)
communications
sequence execution
(*2)
*1 With full-duplex, you can use RS-232C or RS-422A/485 (1:1 and 4-wire connections) can be used. You cannot
use RS-422A/485 1:N or 2-wire connections.
*2 The Flush command can be used at any time to clear the reception buffer.
*3 Although the received data is discarded until completion of Send execution, it is reflected in the character trace.
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Data reception
Character
trace
From Send
All during trace
completion to
execution
Recv comple-
tion, Send com-
pletion to
immediately
before Send
execution
All during com-
All during trace
munications
execution
sequence exe-
cution
4 Using Protocol Macros
Timing chart (example)
Communications
sequence
Recv
Send
Reception buffer
cleared
Data reception
(*3)
Character trace
Communications
sequence
Recv
Send
Reception buffer
cleared (*3)
Data reception
Character trace
Recv
Recv
4
4-17