Omron CJ1W-SCU32 Operation Manual page 418

Machine automation controller, cj / nj-series, serial communications units, cpu unit
Table of Contents

Advertisement

A Standard System Protocol
Sequence
Communications sequence
No.
422 (01A6)
Memory switch set 2
(3000-series)
423 (01A7)
Simple AVG times set
(3000-series)
424 (01A8)
AVG move interval set
(3000-series)
425 (01A9)
AVG move (H) times set
(3000-series)
426 (01AA)
AVG move (L) times set
(3000-series)
427 (01AB)
Automatic detection set
(3000-series)
428 (01AC)
Automatic detection release
(3000-series)
429 (01AD)
Automatic detection list request
(3000-series)
430 (01AE)
3Z4L initialize (3000-series)
431 (01AF)
Measurement condition set
(4000-series)
432 (01B0)
Measurement condition release
(4000-series)
433 (01B1)
Measurement condition list
request (4000-series)
434 (01B2)
Single run measurement start
(4000-series)
435 (01B3)
Deflection measurement start
(4000-series)
436 (01B4)
Continuous measurement start
(scan) (4000-series)
437 (01B5)
Continuous measurement start
(interrupt (*2)) (4000-series)
438 (01B6)
Measurement termination
(4000-series)
439 (01B7)
Data request (4000-series)
440 (01B8)
Forced positive zero
(4000-series)
441 (01B9)
Forced negative zero
(4000-series)
R-84
name
Sets memory switches.
Taking the simple average as the averag-
ing method, sets the averaging times per
measurement interval 4.
Taking the average move as the averag-
ing method, sets the measurement inter-
val number.
Taking the average move and high-speed
data output as the averaging method,
sets the averaging times per measure-
ment interval 4.
Taking the average move and low-speed
data output as the averaging method,
sets the averaging times per measure-
ment interval 4.
Sets work automatic detection function.
Releases the settings of work automatic
detection function.
Requests the settings of work automatic
detection function.
Clears the 3Z4L, sets the mm unit, sets
the memory switches, does not pro-
cesses statistics, and clears all statistic
memory in sequence.
Sets measurement conditions.
Releases measurement conditions that
have been set.
Requests the measurement conditions
that have been set and other settings.
When the sample measurement condi-
tion is from 1 to 999, performs a single
run measurement and requests the mea-
surement results.
Starts a deflection measurement.
Starts a continuous measurement. The
scan notification method is used for
receive data.
Starts a continuous measurement. The
interrupt notification method is used for
receive data.
Terminates continuous measurement.
Requests measurement data in the idle
measurement status or the latch data
generated by the measurement com-
mand.
Sets the forced zero direction to positive
(+).
Sets the forced zero direction to negative
(–).
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
Function
Ladder interface
Send word
Receive
allocation
word alloca-
tion
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
No
No
No
Yes
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No
Yes
No
No (*1)
No
Yes
No
No
No
No