GE L60 Instruction Manual page 565

Line phase comparison system, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 9 of 57)
ADDR
REGISTER NAME
Security (Read/Write Setting)
3280
Administrator Alphanumeric Password Setting
Security (Read Only)
328A
Administrator Alphanumeric Password Status
Security (Read/Write)
328B
Administrator Alphanumeric Password Entry
Security (Read/Write Setting)
3295
Supervisor Alphanumeric Password Setting
Security (Read Only)
329F
Supervisor Alphanumeric Password Status
Security (Read/Write)
32A0
Supervisor Alphanumeric Password Entry
Security (Read/Write Setting)
32AA
Engineer Alphanumeric Password Setting
Security (Read Only)
32B4
Engineer Alphanumeric Password Status
Security (Read/Write)
32B5
Engineer Alphanumeric Password Entry
Security (Read/Write Setting)
32BF
Operator Alphanumeric Password Setting
Security (Read Only)
32C9
Operator Alphanumeric Password Status
Security (Read/Write)
32CA
Operator Alphanumeric Password Entry
Security (Read/Write Setting)
32D4
Observer Alphanumeric Password Setting
Security (Read Only)
32DE
Observer Alphanumeric Password Status
Security (Read/Write)
32DF
Observer Alphanumeric Password Entry
Security (Read Only)
32E9
Reserved for password settings of future roles (63 items)
3328
Security Status Indicator
Security (Read/Write Setting)
3329
Session Lockout
332A
Session Lockout Period
332B
Reserved
Security Supervisory (Read/Write Setting)
3331
Local Authentication Enable
3332
Supervisor Role Enable
3333
Lock Relay
3334
Factory Service Mode Enable
3335
Failed Authentication Alarm Enable
3336
Firmware Lock Alarm
3337
Settings Lock Alarm
Security Command (Read/Write Command)
3339
Operator Logoff
333A
Engineer Logoff
333B
Administrator Logoff
333C
Clear Security Data
Event Recorder (Read Only)
3400
Events Since Last Clear
3402
Number of Available Events
3404
Event Recorder Last Cleared Date
GE Multilin
RANGE
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
---
0 to 1
---
0 to 65535
0 to 65535
0 to 99
0 to 99
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 4294967295
0 to 4294967295
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
---
F202
---
---
F202
---
1
F102
---
1
F202
---
1
F001
---
1
F618
---
1
F001
min
1
F001
---
1
F126
---
1
F126
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F126
---
1
F126
---
1
F126
---
1
F126
---
1
F003
---
1
F003
---
1
F050
DEFAULT
(none)
0 (Disabled)
B
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
(none)
0 (Disabled)
(none)
0
0
3
3
0 (No)
1 (Yes)
1 (Enabled)
1 (Enabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (No)
0 (No)
0 (No)
0 (No)
0
0
0
B-17