GE L60 Instruction Manual page 583

Line phase comparison system, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 27 of 57)
ADDR
REGISTER NAME
7079
Phase Distance Zone 1 Shape
707A
Phase Distance Zone 1 RCA
707B
Phase Distance Zone 1 DIR RCA
707C
Phase Distance Zone 1 DIR Comp Limit
707D
Phase Distance Zone 1 Quad Right Blinder
707E
Phase Distance Zone 1 Quad Right Blinder RCA
707F
Phase Distance Zone 1 Quad Left Blinder
7080
Phase Distance Zone 1 Quad Left Blinder RCA
7081
Phase Distance Zone 1 Volt Limit
7082
Phase Distance Zone 1 Transformer Voltage Connection
7083
Phase Distance Zone 1 Transformer Current Connection
7084
Phase Distance Zone 1 Rev Reach
7085
Phase Distance Zone 1 Rev Reach RCA
7086
Reserved (10 items)
7090
...Repeated for Phase Distance Zone 2
70B0
...Repeated for Phase Distance Zone 3
Ground Distance (Read/Write Grouped Setting) (3 modules)
7130
Ground Distance Zone 1 Function
7131
Ground Distance Zone 1 Current Supervision
7132
Ground Distance Zone 1 Reach
7133
Ground Distance Zone 1 Direction
7134
Ground Distance Zone 1 Comparator Limit
7135
Ground Distance Zone 1 Delay
7136
Ground Distance Zone 1 Block
7137
Ground Distance Zone 1 Target
7138
Ground Distance Zone 1 Events
7139
Ground Distance Zone 1 Shape
713A
Ground Distance Zone 1 Z0 Z1 Magnitude
713B
Ground Distance Zone 1 Z0 Z1 Angle
713C
Ground Distance Zone 1 RCA
713D
Ground Distance Zone 1 DIR RCA
713E
Ground Distance Zone 1 DIR Comp Limit
713F
Ground Distance Zone 1 Quad Right Blinder
7140
Ground Distance Zone 1 Quad Right Blinder RCA
7141
Ground Distance Zone 1 Quad Left Blinder
7142
Ground Distance Zone 1 Quad Left Blinder RCA
7143
Ground Distance Zone 1 Z0M Z1 Magnitude
7144
Ground Distance Zone 1 Z0M Z1 Angle
7145
Ground Distance Zone 1 Voltage Level
7146
Ground Distance Zone 1 Non-Homogeneous Angle
7147
Ground Distance Zone 1 POL Current
7148
Ground Distance Zone 1 Reverse Reach
7149
Ground Distance Zone 1 Reverse Reach RCA
714A
Reserved (7 items)
7151
...Repeated for Ground Distance Zone 2
7172
...Repeated for Ground Distance Zone 3
Line Pickup (Read/Write Grouped Setting)
71F0
Line Pickup Function
71F1
Line Pickup Signal Source
71F2
Line Pickup Phase IOC Pickup
71F3
Line Pickup UV Pickup
71F4
Line End Open Pickup Delay
71F5
Line End Open Reset Delay
GE Multilin
RANGE
0 to 1
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 5
0 to 12
0 to 12
0.02 to 500
30 to 90
---
0 to 1
0.05 to 30
0.02 to 500
0 to 2
30 to 90
0 to 65.535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 10
-90 to 90
30 to 90
30 to 90
30 to 90
0.02 to 500
60 to 90
0.02 to 500
60 to 90
0 to 7
-90 to 90
0 to 5
-40 to 40
0 to 1
0.02 to 500
30 to 90
0 to 65535
0 to 1
0 to 5
0 to 30
0 to 3
0 to 65.535
0 to 65.535
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F120
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
pu
0.001
F001
---
1
F153
---
1
F153
ohms
0.01
F001
degrees
1
F001
---
---
F001
---
1
F102
pu
0.001
F001
ohms
0.01
F001
---
1
F154
degrees
1
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F120
---
0.01
F001
degrees
1
F002
degrees
1
F001
degrees
1
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
ohms
0.01
F001
degrees
1
F001
---
0.01
F001
degrees
1
F002
pu
0.001
F001
degrees
0.1
F002
---
1
F521
ohms
0.01
F001
degrees
1
F001
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
pu
0.001
F001
s
0.001
F001
s
0.001
F001
DEFAULT
0 (Mho)
Fixed in G60
85
85
90
B
1000
85
1000
85
0
0 (None)
0 (None)
200
85
0
0 (Disabled)
200
200
0 (Forward)
90
0
0
0 (Self-reset)
0 (Disabled)
0 (Mho)
270
0
85
85
90
1000
85
1000
85
0
0
0
0
0 (Zero-seq)
200
85
0
0 (Disabled)
0 (SRC 1)
1000
700
150
90
B-35