GE L60 Instruction Manual page 594

Line phase comparison system, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 57)
ADDR
REGISTER NAME
Selector Switch Actual Values (Read Only)
A210
Selector Switch 1 Position
A211
Selector Switch 2 Position
Selector Switch Settings (Read/Write) (2 modules)
A280
Selector 1 Function
B
A281
Selector 1 Range
A282
Selector 1 Timeout
A283
Selector 1 Step Up
A284
Selector 1 Step Mode
A285
Selector 1 Acknowledge
A286
Selector 1 Bit0
A287
Selector 1 Bit1
A288
Selector 1 Bit2
A289
Selector 1 Bit Mode
A28A
Selector 1 Bit Acknowledge
A28B
Selector 1 Power Up Mode
A28C
Selector 1 Target
A28D
Selector 1 Events
A28E
Reserved (10 items)
A298
...Repeated for Selector 2
DNP/IEC Points (Read/Write Setting)
A300
DNP/IEC 60870-5-104 Binary Input Points (256 items)
A400
DNP/IEC 60870-5-104 Analog Input Points (256 items)
FlexCurves C and D (Read/Write Setting)
A600
FlexCurve C (120 items)
A680
FlexCurve D (120 items)
Non Volatile Latches (Read/Write Setting) (16 modules)
A700
Non-Volatile Latch 1 Function
A701
Non-Volatile Latch 1 Type
A702
Non-Volatile Latch 1 Set
A703
Non-Volatile Latch 1 Reset
A704
Non-Volatile Latch 1 Target
A705
Non-Volatile Latch 1 Events
A706
Reserved (4 items)
A70A
...Repeated for Non-Volatile Latch 2
A714
...Repeated for Non-Volatile Latch 3
A71E
...Repeated for Non-Volatile Latch 4
A728
...Repeated for Non-Volatile Latch 5
A732
...Repeated for Non-Volatile Latch 6
A73C
...Repeated for Non-Volatile Latch 7
A746
...Repeated for Non-Volatile Latch 8
A750
...Repeated for Non-Volatile Latch 9
A75A
...Repeated for Non-Volatile Latch 10
A764
...Repeated for Non-Volatile Latch 11
A76E
...Repeated for Non-Volatile Latch 12
A778
...Repeated for Non-Volatile Latch 13
A782
...Repeated for Non-Volatile Latch 14
A78C
...Repeated for Non-Volatile Latch 15
A796
...Repeated for Non-Volatile Latch 16
Digital Counter (Read/Write Setting) (8 modules)
A800
Digital Counter 1 Function
A801
Digital Counter 1 Name
A807
Digital Counter 1 Units
A80A
Digital Counter 1 Block
B-46
RANGE
1 to 7
1 to 7
0 to 1
1 to 7
3 to 60
0 to 65535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 65535
0 to 2
0 to 2
0 to 1
---
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 2
0 to 1
---
0 to 1
---
---
0 to 65535
L60 Line Phase Comparison System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
0.1
F001
---
1
F300
---
1
F083
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F083
---
1
F300
---
1
F084
---
1
F109
---
1
F102
---
1
F001
---
1
F300
---
1
F600
ms
1
F011
ms
1
F011
---
1
F102
---
1
F519
0 (Reset Dominant)
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
---
---
F205
---
---
F206
---
1
F300
DEFAULT
0
1
0 (Disabled)
7
50
0
0 (Time-out)
0
0
0
0
0 (Time-out)
0
0 (Restore)
0 (Self-reset)
0 (Disabled)
0
0
0
0
0
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Counter 1"
(none)
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents