APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 7 of 57)
ADDR
REGISTER NAME
235A
Fault 1 Phase C Current Angle
235B
Fault 1 Phase A Voltage Magnitude
235D
Fault 1 Phase A Voltage Angle
235E
Fault 1 Phase B Voltage Magnitude
2360
Fault 1 Phase B Voltage Angle
2361
Fault 1 Phase C Voltage Magnitude
2363
Fault 1 Phase C Voltage Angle
2364
Fault 1 Type
2365
Fault 1 Location based on Line length units (km or miles)
2366
...Repeated for Fault 2
238C
...Repeated for Fault 3
23B2
...Repeated for Fault 4
23D8
...Repeated for Fault 5
Synchrocheck Actual Values (Read Only) (2 modules)
2400
Synchrocheck 1 Delta Voltage
2402
Synchrocheck 1 Delta Frequency
2403
Synchrocheck 1 Delta Phase
2404
...Repeated for Synchrocheck 2
Autoreclose Status (Read Only)
2410
Autoreclose 1 Count
Remote Double-Point Status Inputs (Read/Write Setting Registers) (5 modules)
2620
Remote Double-Point Status Input 1 Device
2621
Remote Double-Point Status Input 1 Item
2622
Remote Double-Point Status Input 1 Name
2628
Remote Double-Point Status Input 1 Events
2629
... Repeated for Double-Point Status Input 2
2632
... Repeated for Double-Point Status Input 3
263B
... Repeated for Double-Point Status Input 4
2644
... Repeated for Double-Point Status Input 5
IEC 61850 GGIO5 Configuration (Read/Write Setting Registers) (16 modules)
26B0
IEC 61850 GGIO5 uinteger Input 1 Operand
26B1
IEC 61850 GGIO5 uinteger Input 2 Operand
26B2
IEC 61850 GGIO5 uinteger Input 3 Operand
26B3
IEC 61850 GGIO5 uinteger Input 4 Operand
26B4
IEC 61850 GGIO5 uinteger Input 5 Operand
26B5
IEC 61850 GGIO5 uinteger Input 6 Operand
26B6
IEC 61850 GGIO5 uinteger Input 7 Operand
26B7
IEC 61850 GGIO5 uinteger Input 8 Operand
26B8
IEC 61850 GGIO5 uinteger Input 9 Operand
26B9
IEC 61850 GGIO5 uinteger Input 10 Operand
26BA
IEC 61850 GGIO5 uinteger Input 11 Operand
26BB
IEC 61850 GGIO5 uinteger Input 12 Operand
26BC
IEC 61850 GGIO5 uinteger Input 13 Operand
26BD
IEC 61850 GGIO5 uinteger Input 14 Operand
26BE
IEC 61850 GGIO5 uinteger Input 15 Operand
26BF
IEC 61850 GGIO5 uinteger Input 16 Operand
IEC 61850 Received Integers (Read Only Actual Values) (16 modules)
26F0
IEC 61850 Received uinteger 1
26F2
IEC 61850 Received uinteger 2
26F4
IEC 61850 Received uinteger 3
26F6
IEC 61850 Received uinteger 4
26F8
IEC 61850 Received uinteger 5
26FA
IEC 61850 Received uinteger 6
GE Multilin
RANGE
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 11
-3276.7 to 3276.7
-1000000000000 to
1000000000000
0 to 655.35
0 to 359.9
0 to 65535
1 to 32
0 to 64
1 to 64
0 to 1
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
L60 Line Phase Comparison System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
---
1
F148
---
0.1
F002
V
1
F060
Hz
0.01
F001
degrees
0.1
F001
---
1
F001
---
1
F001
---
1
F606
---
1
F205
---
1
F102
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
---
F612
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
DEFAULT
0
0
0
0
0
B
0
0
0 (NA)
0
0
0
0
0
1
0 (None)
"RemDPS Ip 1"
0 (Disabled)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-15