GE L60 Instruction Manual page 685

Line phase comparison system, ur series
Hide thumbs Also See for L60:
Table of Contents

Advertisement

APPENDIX D
 <21> := Measured value, normalized value without quantity descriptor
 <30> := Single-point information with time tag CP56Time2a
 <31> := Double-point information with time tag CP56Time2a
 <32> := Step position information with time tag CP56Time2a
 <33> := Bitstring of 32 bits with time tag CP56Time2a
 <34> := Measured value, normalized value with time tag CP56Time2a
 <35> := Measured value, scaled value with time tag CP56Time2a
 <36> := Measured value, short floating point value with time tag CP56Time2a
 <37> := Integrated totals with time tag CP56Time2a
 <38> := Event of protection equipment with time tag CP56Time2a
 <39> := Packed start events of protection equipment with time tag CP56Time2a
 <40> := Packed output circuit information of protection equipment with time tag CP56Time2a
Either the ASDUs of the set <2>, <4>, <6>, <8>, <10>, <12>, <14>, <16>, <17>, <18>, and <19> or of the set
<30> to <40> are used.
Process information in control direction
 <45> := Single command
 <46> := Double command
 <47> := Regulating step command
 <48> := Set point command, normalized value
 <49> := Set point command, scaled value
 <50> := Set point command, short floating point value
 <51> := Bitstring of 32 bits
 <58> := Single command with time tag CP56Time2a
 <59> := Double command with time tag CP56Time2a
 <60> := Regulating step command with time tag CP56Time2a
 <61> := Set point command, normalized value with time tag CP56Time2a
 <62> := Set point command, scaled value with time tag CP56Time2a
 <63> := Set point command, short floating point value with time tag CP56Time2a
 <64> := Bitstring of 32 bits with time tag CP56Time2a
Either the ASDUs of the set <45> to <51> or of the set <58> to <64> are used.
System information in monitor direction
 <70> := End of initialization
System information in control direction
 <100> := Interrogation command
 <101> := Counter interrogation command
 <102> := Read command
 <103> := Clock synchronization command (see Clause 7.6 in standard)
 <104> := Test command
 <105> := Reset process command
 <106> := Delay acquisition command
 <107> := Test command with time tag CP56Time2a
GE Multilin
L60 Line Phase Comparison System
D.1 PROTOCOL
M_ME_ND_1
M_SP_TB_1
M_DP_TB_1
M_ST_TB_1
M_BO_TB_1
M_ME_TD_1
M_ME_TE_1
M_ME_TF_1
M_IT_TB_1
M_EP_TD_1
M_EP_TE_1
M_EP_TF_1
C_SC_NA_1
C_DC_NA_1
C_RC_NA_1
C_SE_NA_1
C_SE_NB_1
C_SE_NC_1
C_BO_NA_1
C_SC_TA_1
C_DC_TA_1
C_RC_TA_1
C_SE_TA_1
C_SE_TB_1
C_SE_TC_1
C_BO_TA_1
M_EI_NA_1
C_IC_NA_1
C_CI_NA_1
C_RD_NA_1
C_CS_NA_1
C_TS_NA_1
C_RP_NA_1
C_CD_NA_1
C_TS_TA_1
D
D-3