B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 22 of 57)
ADDR
REGISTER NAME
Phase Comparison Positive-Sequence Current Fault Detector (Read/Write Grouped Setting)
60A8
Positive-Sequence Current Fault Detector Function
60A9
Positive-Sequence Current Fault Detector Low Pickup
60AA
Positive-Sequence Current Fault Detector High Pickup
60AB
Positive-Sequence Current Fault Detector Block
B
60AC
Positive-Sequence Current Fault Detector Target
60AD
Positive-Sequence Current Fault Detector Events
Phase Comparison Open Breaker Keying (Read/Write Grouped Setting)
60E0
Open Breaker Keying
60E1
Breaker 1 Auxiliary Contact
60E2
Breaker 1 Supervision Element
60E3
Breaker 2 Auxiliary Contact
60E4
Breaker 2 Supervision Element
60E5
Weak-Infeed Keying
60E6
Supervision Element
60E7
Infeed Pickup Delay
60E8
Infeed Reset Delay
60E9
Open Breaker Keying Pickup Delay
60EA
Open Breaker Keying Reset Delay
Phase Comparison Trip Scheme (Read/Write Grouped Setting)
60F0
87PC Function
60F1
87PC Channel Loss
60F2
87PC Block
60F3
87PC Target
60F4
87PC Events
60F5
87PC Scheme Select
60F6
87PC Scheme Signal
60F7
87PC Signal Source
60F8
87PC FDL Pickup
60FA
87PC FDH Pickup
60FB
87PC Mixed Signal K
60FE
87PC Phase Delay Channel 1
6100
87PC Phase Delay Channel 2
6106
87PC Transient Pickup
610A
87PC Asymmetry Channel 1
610E
87PC Asymmetry Channel 2
6110
87PC Stability Angle
6112
87PC Transient Reset
6113
87PC Received Volts Channel 1
6114
87PC Received Volts Channel 2
6115
87PC High-Speed Contact 1
6116
87PC High-Speed Contact 2
6117
87PC FDL AUX
6118
87PC FDH AUX
6119
87PC Reset Delay
611A
87PC Mixed Signal Reference Angle
611B
87PC Trip Security
611C
87PC Second Coincidence Timer
611D
87PC Enhanced Stability Angle
611E
87PC FDH Supervision
611F
87PC Pickup Delay
6120
87PC Stop Tx
6121
87PC Tx Reset Delay
B-30
RANGE
0 to 1
0.2 to 5
0.5 to 15
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 50
0 to 50
0 to 50
0 to 50
0 to 1
0 to 500
0 to 65535
0 to 2
0 to 1
0 to 8
0 to 2
0 to 1
0.02 to 15
0.05 to 15
0 to 0.25
0 to 30
0 to 30
0 to 65.535
-5 to 5
-5 to 5
40 to 140
0 to 65.535
0 to 125
0 to 125
0 to 64
0 to 64
0 to 65535
0 to 65535
0 to 200
0 to 359
0 to 1
10 to 200
40 to 180
0 to 65535
0 to 50
0 to 65535
0 to 1000
L60 Line Phase Comparison System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
pu
0.01
F001
pu
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
---
1
F102
ms
1
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F088
1 (2TL-TR-SPC-2FC)
---
1
F150
0 (MIXED I_2 - K*I_1)
---
1
F089
pu
0.01
F001
pu
0.01
F001
---
0.01
F001
ms
0.001
F003
ms
0.001
F003
s
0.001
F001
ms
0.1
F002
ms
0.1
F002
degrees
5
F001
s
0.001
F001
V
0.1
F001
V
0.1
F001
---
1
F490
---
1
F490
---
1
F300
---
1
F300
ms
1
F001
°
1
F001
---
1
F534
0 (First Coincidence)
ms
1
F001
°
5
F001
---
1
F300
ms
1
F001
---
1
F300
ms
1
F001
DEFAULT
0 (Disabled)
50
75
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
0
0
0
0
0
35
0
0
0 (Disabled)
0
0
0 (Self-reset)
0 (Disabled)
0 (One Source
Current)
50
75
20
0
0
30
0
0
75
30
120
120
0
0
0
0
30
0
40
110
0
0
0
0