Alarm■Code
Location■
Alarm■
Description
Code
Code
00
0085 A■notice■of■stat
00
0246 For■R&D
00
0247 For■R&D
01
0001 Disabled■to■obtain■counter■
values■for■a■certain■period■of■
time
01
0004 Notification■of■IP■address■
change
01
0005 Machine■is■in■restricted■
operation■mode
01
0010 The■configuration■of■an■
option■controlled■by■the■Main■
Controller■has■been■changed
01
0020 The■configuration■of■an■option■
controlled■by■the■RCON■has■
been■changed
01
0030 The■configuration■of■an■option■
controlled■by■the■DCON■has■
been■changed
02
0025 Insufficient■Scanner■Unit■LED■
light■intensity■alarm
7
Error•Jam•Alarm■>■Alarm■Code
Details
-
-
-
Counter■information■is■not■set■to■UGW■
*■Not■displayed■on■service■mode■history■due■to■the■
alarm■being■generated■by■UGW
IP■address■has■been■changed■
*■Not■displayed■on■service■mode■history■due■to■the■
alarm■being■generated■by■UGW
The■machine■has■entered■limited■function■mode■due■
to■some■reasons■
*■Not■displayed■on■service■mode■history■due■to■the■
alarm■being■generated■by■UGW
A■change■in■configuration■of■an■option■such■as■a■
change■in■the■configuration■of■the■Fax■Board,■a■
change■in■the■configuration■of■the■Voice■Board,■or■
a■change■in■the■configuration■of■the■option■HDD,■
which■requires■turning■OFF■and■then■ON■the■power,■
was■detected.
Detection■condition/timing:
At■the■time■of■startup■only
Remedy:
Turn■OFF■and■then■ON■the■main■power.
Due■to■a■change■in■the■configuration■related■to■the■
scanner,■a■change■in■the■hardware■configuration■
which■requires■turning■OFF■and■then■ON■the■power■
was■detected.
Detection■condition/timing:
At■the■time■of■startup■only
Remedy:
Turn■OFF■and■then■ON■the■main■power.
Due■to■a■change■in■the■configuration■related■to■the■
printer,■a■change■in■the■hardware■configuration■
which■requires■turning■OFF■and■then■ON■the■power■
was■detected.
Detection■condition/timing:
At■the■time■of■startup■only
Remedy:
Turn■OFF■and■then■ON■the■main■power.
In■the■case■that■the■light■intensity■is■insufficient■at■
LED■lighting.■(Some■of■the■LEDs■are■OFF.■Scanning■
can■be■continued.)
7
Error•Jam•Alarm■>■Alarm■Code
Location■
Alarm■
Description
Code
Code
04
0001 Cassette■1■Lifter■error
7-113
Details
Cause:■Error■in■the■Lifter■Motor■or■the■Lifter■Sensor.
Measures:
1.■While■the■Cassette■1■is■removed,■turn■ON■the■
power■and■then■insert■the■Cassette■1,■and■check■
the■operation■sound■of■the■motor.
When■there■is■operation■sound■of■the■motor,■
check■if■the■Middle■Plate■has■been■lifted■up.
When■the■Middle■Plate■has■been■lifted■up:
1-1.■Check■that■the■Cassette■1■Lifter■Sensor■
has■been■properly■installed.
1-2.■Check■the■harness/connector■between■
the■DC■Controller■and■the■Cassette■1■Lifter■
Sensor.
1-3.■Check■the■Cassette■1■Lifter■Sensor.
1-4.■Replace■the■DC■Controller■PCB.
When■the■Middle■Plate■has■not■been■lifted■up:
2-1.■Check■the■condition■of■the■gear■at■the■host■
machine■side■(to■see■if■there■is■missing■or■swing■
with■the■gear).
2-2.■Check■the■Cassette■1■Lifter■Motor.
2-3.■Replace■the■DC■Controller■PCB.
When■there■is■no■operation■sound■of■the■motor,■
check■the■followings:
3-1.■Check■the■harness/connector■between■the■DC■
Controller■and■the■Cassette■1■Lifter■Motor.
3-2.■Check■conduction■of■the■fuse■in■the■DC■
Controller.
3-3.■Check■the■condition■of■the■gear■at■the■host■
machine■side■(to■see■if■there■is■missing■or■swing■
with■the■gear).
3-4.■Check■the■Cassette■1■Lifter■Motor.
3-5.■Replace■the■DC■Controller.