Disassembly/Assembly■>■Original■Exposure■System■>■Removing■the■Reader■Scanner■Unit■>■Procedure
Original■Exposure■System
Removing■the■Reader■Scanner■Unit
■ Procedure
1)■Open■the■ADF■Unit.
2)■Remove■the■Glass■Retainer■(Right)■[1]■and■then■remove■the■Copy■Board■Glass■[2].
•■ 2■Screws■[3]
2x
4
Disassembly/Assembly■>■Original■Exposure■System■>■Removing■the■Reader■Scanner■Unit■>■Procedure
F-4-69
[3]
[1]
[2]
F-4-70
CAUTION:
Grease■is■applied■on■the■2■Rail■Shafts■[1]■of■the■Reader■Scanner■Unit.■If■you■have■
touched■the■grease,■be■careful■not■to■put■it■to■other■parts.
3)■Move■the■belt■[1],■and■move■the■Reader■Scanner■Unit■[2]■to■the■cut■-off■of■the■Reader■Unit.■
[2]
[1]
4-42
[1]
F-4-71
[3]
[2]
F-4-72
4-42