COPIER>FUNCTION>INSTALL
E-RDS
Set use/no use of Embedded-RDS function
Lv.1 Details
To set whether to use the Embedded-RDS function.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
0 to 1
0: Not used, 1: Used (All the counter information is sent.)
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-
LOG, RGW-ADR
COPIER> FUNCTION> CLEAR> ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
RGW-PORT
Set port number of Sales Co's server
Lv.1 Details
To set the port number of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
1 to 65535
Default value
443
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG,
RGW-ADR
COPIER> FUNCTION> CLEAR> ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
COM-TEST
Dspl connect result w/ Sales Co's server
Lv.1 Details
To display the result of the connection test with the sales company's
server.
Use case
When using Embedded-RDS
Adj/set/operate method Select the item, and then press OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
During operation: ACTIVE, When connection is completed: OK, When
connection is failed: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG,
RGW-ADR
COPIER> FUNCTION> CLEAR> ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
8
Service Mode > COPIER > FUNCTION > INSTALL
8
Service Mode > COPIER > FUNCTION > INSTALL
COPIER>FUNCTION>INSTALL
COM-LOG
Dspl connect error dtl w/Sales Co's sver
Lv.1 Details
To display error information when the connection with the sales
company's server failed.
Use case
When using Embedded-RDS
Adj/set/operate method N/A (Display only)
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
Year, date, time, error code, error detail information (maximum 128
characters)
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
RGW-ADR
COPIER> FUNCTION> CLEAR> ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
RGW-ADR
URL setting of Sales Company's server
Lv.1 Details
To set the URL of the sales company's server to be used for
Embedded-RDS.
Use case
When using Embedded-RDS
Adj/set/operate method 1) Select the URL.
2) Enter the URL, and then press OK key.
3) Turn OFF/ON the main power switch.
Caution
- Do not use Shift-JIS character strings.
- Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG and
RGW-ADR as a set.
Display/adj/set range
URL
Default value
https://a01.ugwdevice.net/ugw/agentif010
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
COM-LOG
COPIER> FUNCTION> CLEAR> ERDS-DAT
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol