■ ANALOG

COPIER>DISPLAY>ANALOG
TEMP
Display of outside temperature
Lv.1 Details
To display the temperature outside the machine.
This is measured by the Environment Sensor that detects the outside
air.
Use case
When checking the temperature outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 60
Unit
1 deg C
Appropriate target value Room temperature+/-5 deg C
HUM
Display of outside humidity
Lv.1 Details
To display the humidity outside the machine.
This is measured by the Environment Sensor that detects the outside
air.
Use case
When checking the humidity outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 %
Appropriate target value 1 - 99
ABS-HUM
Display of outside moisture content
Lv.1 Details
To display the absolute moisture content outside the machine.
This is measured by the Environment Sensor that detects the outside
air.
Use case
When checking the moisture content outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 g/m3
Appropriate target value 0 - 50
FIX-E
Dspl of Fixing Heater center temperature
Lv.1 Details
To display the center temperature of the Fixing Heater detected by
the Main Thermistor.
Use case
When checking the temperature at the center of Fixing Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
Appropriate target value 20 - 230
FIX-E2
Dspl Fixing Heater front edg temperature
Lv.1 Details
To display the front edge temperature of the Fixing Heater detected
by the Sub Thermistor 1.
Use case
When checking the edge temperature of the Fixing Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
Appropriate target value 20 - 250
8
Service Mode > COPIER > DISPLAY > ANALOG
8
Service Mode > COPIER > DISPLAY > ANALOG
COPIER>DISPLAY>ANALOG
TEMP2
Display of estimated inside temperature
Lv.1 Details
To display the temperature inside the machine (around the
Developing Unit) estimated from the temperature in the Laser
Scanner Unit.
Use case
When checking the temperature inside the machine (around the
Developing Unit)
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 deg C
Appropriate target value Room temperature - Room temperature+15 deg C
HUM2
Display of estimated inside humidity
Lv.1 Details
To display the estimated relative humidity inside the machine that is
calculated from the estimated temperature inside the machine and
moisture content outside the machine.
Use case
When checking the humidity inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 %
Appropriate target value 1 - 99
FIX-E3
Dspl Fixing Heater rear edge temperature
Lv.1 Details
To display the rear edge temperature of the Fixing Heater detected
by the Sub Thermistor 2.
Use case
When checking the edge temperature of the Fixing Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
Appropriate target value 20 - 250
8-31
T-8-9
8-31