Canon imageRUNNER ADVANCE C3325 Series Service Manual page 734

Hide thumbs Also See for imageRUNNER ADVANCE C3325 Series:
Table of Contents

Advertisement

COPIER>OPTION>USER
PS-MODE
Setting of compatible mode at PS usage
Lv.2 Details
To set the image processing at PS print.
Set 8 when line width differs depending on the drawing position
although the same line width is set.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 65535
0 to 7: Spare
8: Strokeadjustment is enabled.
9 to 65535: Spare
Default value
0
CNCT-RLZ
ON/OFF of connection serialize function
Lv.2 Details
Connection serialize is a function to assure job grouping function of
imageWARE Output Manager Select Edition V1.0.
When 1 is set, mismatch in job order can be prevented because
the machine does not receive job data from other connection until it
completes job data reception from the current connection.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
Connection: Connection to be established through network between
multiple hosts (PC, etc).
Job grouping function: A function of imageWARE Output Manager
Select Edition V1.0. It enables to prevent job interruption from other
PC by grouping jobs (sending multiple jobs in 1 session at job
transmission).
COUNTER7
Setting of software counter 7
Lv.1 Details
To set counter type for software counter 7 on the Counter Check
screen.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
0
COUNTER8
Setting of software counter 8
8
Service Mode > COPIER > OPTION > USER
8
Service Mode > COPIER > OPTION > USER
COPIER>OPTION>USER
Lv.1 Details
To set counter type for software counter 8 on the Counter Check
screen.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: No registration
Default value
0
8-183