Alarm Function - JRC JAN-701B Instruction Manual

Ecdis
Hide thumbs Also See for JAN-701B:
Table of Contents

Advertisement

9.1 Alarm Function

(1) No Alarm
Category*1
Message*2
No Alarm
No Alarm
(2) System Alarm
Category*1
Message*2
No.1
POSN 1(Data)
Position
Data Alarm
POSN1 not fix
POSN1(NON-WGS84)
No.2
POSN 2(Data)
Position
Data Alarm
POSN2 not fix
POSN2(NON-WGS84)
No.1
POSN1 shifted
Position Shift
Alarm
Position
Position difference
Difference
exceed
Alarm
Radar Data
PROC(AZI)
Alarm
PROC(HL)
PROC(Trigger)
PROC(Video)
RIB(Data)
PROC(Reverse)
PROC(INT)
ASIC1 to Radar
Target Track
TT(Data)
Data Alarm
SRB Data
SRB(Data)
Alarm
GYRO Data
Gyro I/F(Gyro)
Alarm
Heading(Data)
LOG Data
Gyro I/F(Log)
Alarm
Log(Data)
Autopilot
Autopilot(DATA)
Data Alarm
Hardware
Fan(CPU)
Alarm
CPU High Temperature
Fan(Main PWR)
Fan(ATX PWR)
Fan(LCD)
Disk1 Error
Disk2 Error
AC offline
9 Reference
Alarm
Alarm Type*3
Colour*3
Normal State
Green
Alarm
Alarm Type*3
Colour*3
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
Alarm
Red
9-2
Buzzer Type*4
Meaning*5
Silent
No Alarm
Buzzer Type*4
Meaning*5
System Alarm
POSN1 (primary) is defective or
communication line is cut.
System Alarm
POSN1 is not fixed.
System Alarm
Geodetic system between chart and
measured position information being
received differs.
System Alarm
POSN2 (secondary) is defective or
communication line is cut.
System Alarm
POSN2 is not fixed.
System Alarm
Geodetic system between chart and
measured position information being
received differs.
System Alarm
The shift amount of the primary
position exceeds the limit being set.
System Alarm
The difference between the primary
and second positions exceeds the
limit being set.
System Alarm
Rotation signal (BP) is out of
specifications.
System Alarm
Rotation signal (BZ) is out of
specifications.
System Alarm
Trigger signal is out of specifications
or signal line is cut.
System Alarm
Video signal is out of specifications.
System Alarm
Error occurred in the radar interface
board.
System Alarm
Error by reverse-rotation in the signal
processing part.
System Alarm
Error in interrupting of stun in the
signal processing part.
System Alarm
Error in interrupting from ASIC1 to
radar DSP
System Alarm
Target Track is defective or signal
line is cut.
System Alarm
Error occurred in the serial relay
board
System Alarm
Gyro is defective.
System Alarm
Error occurred in the heading data of
gyro interface or its line is cut.
System Alarm
Log is defective.
System Alarm
Error occurred in the log data of log
interface or its line is cut.
System Alarm
Autopilot is defective or
communication line is cut.
System Alarm
CPU fan is defective.
System Alarm
CPU temperature is rising.
System Alarm
Main power supply fan is defective.
System Alarm
ATX power supply fan is defective.
System Alarm
LCD fan is defective.
System Alarm
Disk1 is defective.
System Alarm
Disk2 is defective.
System Alarm
AC power is offline.
Condition*6
Condition*6
Position measuring
instrument is
connected
(including DR).
Position measuring
instrument is
connected
(including DR).
User setting
User setting.
Position measuring
instrument is
connected to
POSN2
(including DR).
During radar
display
During TT
display
Always
Gyro is
connected.
Log is
connected.
Autopilot is
connected.
Always

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jan-901b

Table of Contents