8.
Do one of the following:
•
If the purpose of the conversion kit installation is to switch the server to rack mode operation, power
up the server.
•
If the purpose of the conversion kit installation is to ship a rack-installed server, install the shipping
hardware
9.
Connect each power cord to the power source.
10. Power up the server on page 38.
The installation is complete.
Drive cage options
The server supports several drive cage options. If the maximum number of drives are installed in all three
drive boxes, the fan cage option is required.
4 LFF non-hot-plug drive cage option
The server supports the 4 LFF non-hot-plug drive cage option. This option:
•
Can be installed in boxes 1–3
•
Cannot be installed together with the 4 LFF and 8 SFF hot-plug drive cage options
•
Supports SATA drives only
Kit contents
•
4 LFF non-hot-plug drive cage
•
SATA-power split cable
•
T-15 screws (20) – There are four loose screws in the kit, plus 16 screws preinstalled on top of the drive
cage.
Installing the 4 LFF non-hot-plug drive cage
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
88