Nvme Ssd Components - HPE ProLiant ML350 Gen10 User Manual

Hide thumbs Also See for ProLiant ML350 Gen10:
Table of Contents

Advertisement

CAUTION:
Dynamic Smart Array is not supported when the boot mode is configured to Legacy BIOS Mode.
Enabling Dynamic Smart Array RAID results in data loss or data corruption on existing SATA drives.
Back up all drives before enabling this option.
See your operating system documentation before enabling SATA AHCI support to ensure your base
media drivers support this feature.
Prerequisites
The correct operating system drivers for your selected option.
Boot Mode is set to UEFI Mode.
Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > System Options > SATA Controller Options > Embedded SATA Configuration.
2. Ensure that you are using the correct ACHI or RAID system drivers for your SATA option.
3. Select a setting.
Enable SATA AHCI Support—Enables the embedded chipset SATA controller for AHCI.
Enable Dynamic Smart Array RAID Support—Enables the embedded chipset SATA controller for
Dynamic Smart Array RAID.
4. Save your setting.

NVMe SSD components

The NVMe SSD is a PCIe bus device. A device attached to a PCIe bus cannot be removed without allowing
the device and bus to complete and cease the signal/traffic flow.
CAUTION:
Do not remove an NVMe SSD from the drive bay while the Do not remove LED is flashing. The Do not
remove LED flashes to indicate that the device is still in use. Removing the NVMe SSD before the
device has completed and ceased signal/traffic flow can cause loss of data.
NVMe SSD components
21