If you are replacing the factory installed ground lug, use the KST RNB5-5 crimp terminal ring or equivalent.
Use an M5-0.80 x 8 screw to attach the ground lug to the power input module.
WARNING:
To reduce the risk of electric shock or energy hazards:
This equipment must be installed by trained service personnel, as defined by the NEC and IEC
60950-1, Second Edition, the standard for Safety of Information Technology Equipment.
Connect the equipment to a reliably grounded secondary circuit source. A secondary circuit has no
direct connection to a primary circuit and derives its power from a transformer, converter, or
equivalent isolation device.
The branch circuit overcurrent protection must be rated 27 A.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank to
cool before touching it.
CAUTION:
This equipment is designed to permit the connection of the earthed conductor of the DC supply circuit to
the earthing conductor at the equipment.
If this connection is made, all of the following must be met:
This equipment must be connected directly to the DC supply system earthing electrode conductor or
to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing
electrode conductor is connected.
This equipment must be located in the same immediate area (such as adjacent cabinets) as any
other equipment that has a connection between the earthed conductor of the same DC supply circuit
and the earthing conductor, and also the point of earthing of the DC system. The DC system must be
earthed elsewhere.
The DC supply source is to be located within the same premises as the equipment.
Switching or disconnecting devices must not be in the earthed circuit conductor between the DC
source and the point of connection of the earthing electrode conductor.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Procedure
1.
If you are installing a power supply in the power supply bay 2, remove the power supply blank.
Hardware options installation
73