Installing an NVMe SSD

CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
IMPORTANT:
During high-performance workloads, the operation of 1.6 TB or higher capacity NVMe SSDs can cause
the fans to operate at high speeds to maintain optimum system cooling. This high-speed fan operation
leads to a sound pressure level of between 50 dB(A) to 55 dB(A). Hewlett Packard Enterprise
recommends taking this possible acoustic condition into consideration when selecting a site for a server
that has this type of SSD option installed
Prerequisites
Before you perform this procedure:
Make sure that the fan cage is installed.
Make sure that the NVMe SSD Express Bay cage is installed.
Make sure that the NVMe SSD option is available.
Procedure
1. Open the front bezel on page 39.
2. If installing drives in bay 2-8, remove the drive blank.
3. Prepare the drive.
4. Install the drive.
Installing an NVMe SSD
69