Fan Cage Option; Fan Cage Implementation; Fan Population And Hot-Plug Support - HPE ProLiant ML350 Gen10 User Manual

Hide thumbs Also See for ProLiant ML350 Gen10:
Table of Contents

Advertisement

Fan cage option

The server supports a fan cage option. This fan cage is required for specific hardware configurations.
Kit contents
Fan cage with four preinstalled fans
Fan cage brackets (2)

Fan cage implementation

The fan cage is required to meet the system thermal requirements for the following configurations:
Server operating in rack mode
Dual-processor configuration
Server with the following drive box configurations:
The maximum number of drives is installed in boxes 1, 2, and 3 (12 drives for LFF configuration, 24
drives for SFF configuration).
The maximum number of drives is installed in boxes 2 and 3, and at least two media devices are
installed.
Server with the following options installed:
NVMe SSDs
M.2 SSDs
SFF SAS drives with 10K or 15K rpm rate
Smart Array P-class 800-series Gen10 controllers*
GPUs*
HPE EDR InfiniBand adapters*
High-performance NIC controllers*
For specific models covered by the options marked with an asterisk (*), see the product QuickSpecs on
the server website at http://www.hpe.com/servers/ml350-gen10.
ASHRAE A3 and A4 compliant configurations
For more information, see the Hewlett Packard Enterprise website.

Fan population and hot-plug support

The number of fans installed in the server determines fan redundancy. When redundant fan mode is enabled,
hot-plug fan operation is supported.
In this server, fan operation can either be one of the following:
Hot-plug – A failed fan can be replaced without powering down the server
Non-hot-plug – To replace a failed fan, the user must either:
Keep the server powered on and complete the fan replacement within 30 seconds of opening the
access panel, or
Power down and disconnect all power from the server before removing the access panel for fan
replacement.
Fan cage option
107