Fan cage option
The server supports a fan cage option. This fan cage is required for specific hardware configurations.
Kit contents
•
Fan cage with four preinstalled fans
•
Fan cage brackets (2)
Fan cage implementation
The fan cage is required to meet the system thermal requirements for the following configurations:
•
Server operating in rack mode
•
Dual-processor configuration
•
Server with the following drive box configurations:
◦
The maximum number of drives is installed in boxes 1, 2, and 3 (12 drives for LFF configuration, 24
drives for SFF configuration).
◦
The maximum number of drives is installed in boxes 2 and 3, and at least two media devices are
installed.
•
Server with the following options installed:
◦
NVMe SSDs
◦
M.2 SSDs
◦
SFF SAS drives with 10K or 15K rpm rate
◦
Smart Array P-class 800-series Gen10 controllers*
◦
GPUs*
◦
HPE EDR InfiniBand adapters*
◦
High-performance NIC controllers*
For specific models covered by the options marked with an asterisk (*), see the product QuickSpecs on
the server website at http://www.hpe.com/servers/ml350-gen10.
•
ASHRAE A3 and A4 compliant configurations
For more information, see the Hewlett Packard Enterprise website.
Fan population and hot-plug support
The number of fans installed in the server determines fan redundancy. When redundant fan mode is enabled,
hot-plug fan operation is supported.
In this server, fan operation can either be one of the following:
•
Hot-plug – A failed fan can be replaced without powering down the server
•
Non-hot-plug – To replace a failed fan, the user must either:
◦
Keep the server powered on and complete the fan replacement within 30 seconds of opening the
access panel, or
◦
Power down and disconnect all power from the server before removing the access panel for fan
replacement.
Fan cage option