Specifications; Environmental Specifications; Mechanical Specifications - HPE ProLiant ML350 Gen10 User Manual

Hide thumbs Also See for ProLiant ML350 Gen10:
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m
(10,000 ft) is applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper
limit and rate of change might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C
per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per
every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise
website.

Mechanical specifications

Specification
Tower model
Height
Depth
Width
Weight, minimum
Weight, maximum
Rack model
1
Value
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
46.25 cm (18.21 in)
64.8 cm (25.51 in)
17.4 cm (6.85 in)
21 kg (46.30 lb)
41 kg (90.39 lb)
Table Continued