  • Page 1 HPE ProLiant ML110 Gen11 Server User Guide HPE ProLiant ML110 Gen11 Server User Guide Part Number: 30-896389FE-002 Published: November 2023 Edition: 2...
  • Page 2 HPE ProLiant ML110 Gen11 Server User Guide HPE ProLiant ML110 Gen11 Server User Guide Abstract Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels, and are familiar with the weight and stability precautions for rack installations.
  • Page 3 Media device screws Trusted Platform Module 2.0 Trusted Platform Module 2.0 guidelines BitLocker recovery key/password retention guidelines HPE NS204i-u Boot Device components HPE NS204i-u Boot Device LED definitions Setup Initial system installation HPE Installation Service Setting up the server Operational requirements...
  • Page 4 Power requirements Electrical grounding requirements Rack warnings and cautions Server warnings and cautions Electrostatic discharge Operations Power down the server Extend the server from the rack Remove the server from the rack Remove the front bezel Position the tower server for hardware configuration Remove the access panel Remove the system air baffle Remove the riser cage...
  • Page 5 Installing an M.2 SSD Redundant fan option kit Fan mode behavior Installing the redundant fan option kit Memory option HPE SmartMemory speed and population information DIMM installation guidelines Installing a DIMM Riser cage and secondary riser option Installing the riser cage option...
  • Page 6 VGA cabling Front I/O module cabling Configuration resources Updating firmware or system ROM Configuring the server Configuring storage controllers Managing the HPE NS204i-u Boot Device Deploying an OS Configuring security Optimizing the server Server management Managing Linux-based high performance compute clusters...
  • Page 7 Environmental specifications Mechanical specifications Power supply specifications HPE 500 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 1000 W Flex Slot Titanium Hot-plug Power Supply HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply...
  • Page 8: Component Identification

    HPE NS204i-u Boot Device components HPE NS204i-u Boot Device components HPE NS204i-u Boot Device LED definitions HPE NS204i-u Boot Device LED definitions Front panel components Front panel components LFF non-hot-plug drive configuration LFF non-hot-plug drive configuration HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 9 LFF hot-plug drive configuration LFF hot-plug drive configuration HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 10 SFF hot-plug drive configuration SFF hot-plug drive configuration HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 11 The Service Port is a USB port with the label iLO iLO on supported servers and compute modules. To find out if your server or compute module supports this feature, see the server specifications document at the following website: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 12: Front Panel Leds And Button

    You cannot access the server by connecting to the Service Port. You cannot access the connected device from the server. For more information about the iLO Service Port, see the iLO user guide at the following website: https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6. Front panel LEDs and button...
  • Page 13 When the four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see Front panel LED power fault codes. If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use HPE iLO to review the system health status.
  • Page 14: Front Panel Led Power Fault Codes

    Power backplane 8 flashes Storage backplane 9 flashes Power supply 10 flashes PCIe expansion cards installed in riser board 11 flashes Chassis 12 flashes GPU card 13 flashes Rear panel components Rear panel components HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 15 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 16: Rear Panel Leds

    The embedded video controller in the iLO 6 chipset does not support dual display or screen extension mode. To enable dual display mode, install a compatible PCIe5 graphics card that supports this feature in the slots 2 and 3. Rear panel LEDs Rear panel LEDs HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 17 Solid green Network link No network link NIC link LED Solid green Network link No network link NIC status LED Solid green Linked to network Flashing green Network active No network link HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 18: System Board Components

    System board components System board components HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 19 System maintenance switch Subtopics Subtopics System maintenance switch descriptions System maintenance switch descriptions DIMM label identification DIMM label identification DIMM slot numbering DIMM slot numbering Heatsink and processor socket components Heatsink and processor socket components HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 20: System Maintenance Switch Descriptions

    To determine DIMM characteristics, see the label attached to the DIMM. The information in this section helps you to use the label to locate specific information about the DIMM. For more information about product features, specifications, options, configurations, and compatibility, see the HPE DDR5 SmartMemory QuickSpecs: https://www.hpe.com/docs/server-memory...
  • Page 21: Dimm Slot Numbering

    B—50-42-42 (for 128 GB and 256 GB capacities) DIMM type E—UDIMM (unbuffered with ECC) R—RDIMM (registered) The maximum memory speed and capacity is a function of the memory type, memory configuration, and processor model. DIMM slot numbering DIMM slot numbering HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 22 The arrow points to the front of the server. Heatsink and processor socket components Heatsink and processor socket components A standard heatsink is shown, your heatsink might look different. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 23 M.2 SSD numbering The server has two M.2 slots on the system board. These slots support NVMe and SATA SSDs in 2280 and 22110 form factors . Mixed SSD type configuration is not supported. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 24: Riser Board Components

    Slot 3 PCIe5 x16 (16, 8, 4) Full-height, full-length Slot 2 PCIe5 x16 (16, 8, 4) Full-height, half-length Half-height, half-length (low-profile) Slot 3 supports a single-width accelerator. Slot 2 supports a single-width or double-width accelerator. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 25 HPE Basic Drive LED definitions Basic Drive LED definitions The HPE Basic drive carrier has the following LEDs: Amber/blue LED—Managed by the drive backplane in conjunction with the storage controller and is used to indicate drive status. Green LED—Managed by the drive itself and indicates the drive activity.
  • Page 26 SFF basic drive carrier basic drive carrier The SFF basic drive carrier supports hot-plug SAS or SATA drives . HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 27: Drive Bay Numbering

    Mixed hot-plug drive bay numbering Mixed hot-plug drive bay numbering LFF non-hot-plug drive bay numbering LFF non-hot-plug drive bay numbering This server supports up to 8 SATA drives in two LFF non-hot-drive boxes. Tower orientation Tower orientation HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 28 Rack orientation Rack orientation LFF hot-plug drive bay numbering LFF hot-plug drive bay numbering HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 29 LFF hot-plug drive box uses the 4 LFF 12G x1 SAS / SATA UBM3 drive backplane. For more information on the drive backplane description, see Drive backplane naming. Tower orientation Tower orientation Rack orientation Rack orientation HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 30 8 SFF 24G x1 SAS / SATA UBM3 BC 8 SFF 24G x1 SAS / SATA UBM6 BC For more information on the drive backplane description, see Drive backplane naming. Tower orientation Tower orientation HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 31 Rack orientation Rack orientation Mixed hot-plug drive bay numbering Mixed hot-plug drive bay numbering HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 32 This server supports one mixed hot-plug drive configuration with the LFF drive CTO server option: Box 1 — 4 LFF hot-plug drive Box 2 — 8 SFF hot-plug drive Tower orientation Tower orientation Rack orientation Rack orientation HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 33 Drive backplane naming This topic explains the features represented in the drive backplane naming. This naming convention was adopted starting in the HPE Gen11 server release. Your server might not support all the features listed in this topic. For server-specific support information, see the server guides: Drive backplane support, see Drive bay numbering.
  • Page 34: Fan Numbering

    CPU direct attach or tri-mode controller support for x4 U.3 NVMe or x1 SAS and SATA drives. CPU direct attach or tri-mode controller support for x4 U.2 NVMe drives. Fan numbering Fan numbering HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 35: Media Device Screws

    3 and 4 Redundant system fan Media device screws Media device screws There are 8 T-15 Torx screws on the server chassis. These screws are provided as spare screws for installing media devices. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 36: Trusted Platform Module

    The TPM 2.0 is supported with specific operating system support such as Microsoft Windows Server 2012 R2 and later. For more information about operating system support, see the product QuickSpecs on the Hewlett Packard Enterprise website (https://www.hpe.com/info/qs https://www.hpe.com/info/qs). For more information about Microsoft Windows BitLocker Drive Encryption feature, see the Microsoft website (https://www.microsoft.com https://www.microsoft.com).
  • Page 37 Recovery Mode after BitLocker detects a possible compromise of system integrity. HPE is not liable for blocked data access caused by improper TPM use. For operating instructions, see the documentation for the encryption technology feature provided by the operating system.
  • Page 38 Item Description Item Description Boot device cage M.2 slots Boot device carriers HPE NS204i-u Boot Device LED definitions HPE NS204i-u Boot Device LED definitions HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 39 Setup Setup This chapter describes general operational requirements and safety reminders, as well as the initial setup procedure for the server. Subtopics Subtopics Initial system installation Initial system installation Operational requirements Operational requirements HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 40 HPE Installation Service provides basic installation of Hewlett Packard Enterprise branded equipment, software products, as well as HPE- supported products from other vendors that are sold by HPE or by HPE authorized resellers. The Installation Service is part of a suite of HPE deployment services that are designed to give users the peace of mind that comes from knowing that their HPE and HPE-supported products have been installed by an HPE specialist.
  • Page 41 Non-OS specific: UEFI System Utilities Windows: Intel VROC GUI, Intel VROC CLI Linux: mdadm CLI For more information on Intel VROC features and configuration, see the Intel Virtual RAID on CPU for HPE Gen11 User Guide: https://hpe.com/support/VROC-Gen11-UG https://hpe.com/support/VROC-Gen11-UG Read the Operational requirements for the server.
  • Page 42: Operational Requirements

    9. After the OS is installed, update the drivers. Operational requirements Operational requirements When preparing the site and planning the installation for the HPE ProLiant ML110 Gen11 Server, be sure to observe the following general operational requirements: Space and airflow requirements...
  • Page 43: Temperature Requirements

    WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 44: Electrical Grounding Requirements

    The full weight of the rack rests on the leveling jacks (feet). The stabilizing feet are attached to the rack if it is a single-rack installation. The racks are coupled together in multiple rack installations. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 45: Server Warnings And Cautions

    CAUTION: CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 46: Electrostatic Discharge

    Power down the server Extend the server from the rack Extend the server from the rack Remove the server from the rack Remove the server from the rack Remove the front bezel Remove the front bezel HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 47: Power Down The Server

    Before you perform this procedure, review the Rack warnings and cautions. Procedure Procedure Slide the server tray out of the rack: 1. Loosen the server tray thumbscrews. 2. Grasp the tray notch and slide the server out of the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 48 3. Disconnect all peripheral cables from the server. 4. Slide the server tray out of the rack: a. Loosen the server tray thumbscrews. b. Grasp the tray notch and slide the server out of the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 49: Remove The Front Bezel

    If you are using the virtual power button in iLO to power the server on/off, you do not need to remove the front bezel. Remove the front bezel only if you need to access the front panel components. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 50: Position The Tower Server For Hardware Configuration

    2. Open the front bezel. 3. Release the bezel hooks from the front panel. Position the tower server for hardware configuration Position the tower server for hardware configuration Procedure Procedure 1. Rotate the chassis feet inward. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 51 2. Place the server on a flat, level surface with the access panel facing up. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 52: Remove The Access Panel

    If the server is in rack mode, remove the server from the rack. 6. Remove the access panel: a. Loosen the access panel thumbscrew. b. Slide the access panel toward the rear panel, and then lift it away from the chassis. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 53: Remove The System Air Baffle

    If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 54 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 6. Remove the access panel . 7. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 55: Install The System Air Baffle

    Simultaneously pull the front and rear riser cage out from the chassis. 9. Disconnect all riser cables from the system board . Install the system air baffle Install the system air baffle About this task About this task HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 56 2. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. 3. Install the system air baffle. Make sure that the alignment hooks are locked on the chassis. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 57: Install The Access Panel

    CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static- sensitive devices. To prevent damage, observe antistatic precautions. Procedure Procedure 1. Position the access panel on the chassis, and then slide it toward the front panel. 2. Tighten the access panel thumbscrew. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 58 3. Perform the post-installation or maintenance steps required by the procedure that required the removal of the access panel. Position the tower server Position the tower server for operation for operation Procedure Procedure 1. Return the server to an upright position. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 59 2. Rotate the chassis feet outward to stabilize the server. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 60: Install The Front Bezel

    3. While pressing the key against the lock, rotate the key to the lock position. 4. (Optional) For later use, store the front bezel keys inside the front bezel. Install the server Install the server into the into the rack rack HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 61 1. Grasp the tray notch to slide the tray out of the rack. 2. Place the server on the tray. Verify that the front panel of the server is aligned with the front of the tray. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 62 3. Press and hold the blue rail-release tabs, and then slide the tray back into the rack. 4. Tighten the server tray thumbscrews. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 63: Power Up The Server

    This chapter provides instructions for installing supported hardware options. To ensure proper server deployment and operation, Hewlett Packard Enterprise recommends installing only HPE‑validated hardware options. To see the list of validated options for this server, see the product QuickSpecs on the HPE ProLiant ML110 Gen11 Server website: https://buy.hpe.com/us/en/p/1014705725...
  • Page 64 Component drivers and firmware TPM recovery key/password BIOS configuration settings—Use the backup and restore function in UEFI System Utilities. For more information, see the UEFI user guide (https://www.hpe.com/info/UEFI-manuals https://www.hpe.com/info/UEFI-manuals). Custom default system settings HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 65: Drive Options

    Customer iLO user name, password, and DNS name iLO configuration settings For servers managed by HPE GreenLake for Compute Ops Management , make sure that you have your HPE GreenLake account ID. For more information, see HPE HPE GreenLake GreenLake for Compute Ops Management Getting Started Guide for Compute Ops Management Getting Started Guide .
  • Page 66: Drive Installation Guidelines

    If the server is in rack mode, remove the server from the rack. 6. If installed, remove the front bezel . 7. Remove the access panel . 8. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 67 9. If a non-hot-plug drive is already installed, disconnect the drive power and SATA cables from the drive. 10. Remove the non-hot-plug drive cage. 11. Remove the correct number of screws from the drive cage. Each drive requires four screws. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 68 12. Install the non-hot-plug drive. 13. Install the non-hot-plug drive cage. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 69 Installing a hot-plug LFF/SFF drive Installing a hot-plug LFF/SFF drive Prerequisites Prerequisites The redundant fan kit is required when installing SFF drives with the following specifications: 15K RPM hard disk drives 24G SAS-4 solid state drives HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 70 To prevent damage, observe antistatic precautions. Procedure Procedure 1. If installed, remove the front bezel . 2. Remove the drive blank. LFF drive blank SFF drive blank 3. Prepare the drive. LFF drive HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 71 SFF drive 4. Install the drive. LFF drive HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 72: Power Supply Options

    5. Determine the status of the drive from the drive LED definitions . 6. Install the front bezel . 7. To configure drive arrays, see the relevant storage controller guide . Results Results The installation is complete. Power supply options Power supply options HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 73: Hot-Plug Power Supply Calculations

    About this task WARNING: WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply, power supply blank, or dual slot power supply adapter to cool before touching it. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 74 1. If you are installing a power supply in the power supply bay 2, remove the power supply blank. Retain the blank for future use. Tower mode Rack mode 2. Immediately slide the power supply into the bay until it clicks into place. Tower mode HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 75 Secure the power cord with the strain relief strap. Roll the extra length of the strap around the power supply handle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 76 Cable management arm Rack rail specifications Rack rail specifications This server supports the HPE tower-to-rack conversion kit (874578-B211) which has the following specifications: Type: Ball-bearing (stab-in) Minimum rail length: 727.50 mm (28.64 in) Rail adjustable range: 570.00–812.00 mm (22.50–32.00 in)
  • Page 77 Loosen the screws on the chassis. b. Detach the chassis feet. 6. Install the rack rails and server tray. 7. Install the server into the rack. 8. Install the cable management arm . HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 78: Install The Rack Rails And Server Tray

    2. Install the sliding rails on the server tray: a. Insert the spools on the sides of the server tray through the notches on the rails. b. Slide the rail towards the rear of the tray to lock it into place. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 79 4. Fasten the mounting rails to the rack columns: a. Retract and hold the rear retention bracket. b. Insert the pins on the mounting flange into the rack column holes. c. Release the rear retention bracket. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 80 Insert the pins on the mounting flange into the rack column holes. f. Release the front retention bracket. 5. Slide the server tray into the rack. The rack rails will click and lock into place when the tray is properly engaged. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 81 Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available. Procedure Procedure 1. Grasp the tray notch to slide the tray out of the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 82 Verify that the front panel of the server is aligned with the front of the tray. 3. Press and hold the blue rail-release tabs, and then slide the tray back into the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 83: Install The Cable Management Arm

    Connect each power cord to the server. b. Connect each power cord to the power source. 6. Tighten the server tray thumbscrews. Install the cable management arm Install the cable management arm HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 84 Insert the outer tab into the mounting rail. c. Insert the retention bracket into the opposite mounting rail. There will be an audible click to indicate that the tabs and bracket are locked into place. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 85 Make sure that the cables and power cords do not extend above the top or below the bottom of the server to which they are attached. Otherwise, the cables might snag on other equipment installed in the rack when the server is extended from or returned to the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 86 To ensure that the cables and cords are secured properly, slide the chassis in and out of the rack. Make sure that there is no risk of accidental disconnection of the peripheral cables and power cords. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 87: Drive Cage Options

    5. If installed, remove the front bezel . 6. Do one of the following: If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 88 If the server is in rack mode, remove the server from the rack. 7. Remove the access panel . 8. Remove the system air baffle. 9. Remove the drive cage blank. 10. Install the non-hot-plug LFF drive . 11. Install the non-hot-plug drive cage. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 89 Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available. About this task About this task The server supports the 4 LFF hot-plug drive cage option. This option: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 90 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 7. Remove the access panel . 8. Remove the system air baffle. 9. Remove the drive cage blank. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 91 LFF hot-plug drive controller cables Drive power cable 13. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 92 Disconnect each power cord from the power source. b. Disconnect each power cord from the server. 4. Disconnect all peripheral cables from the server. 5. If installed, remove the front bezel . 6. Do one of the following: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 93 8. Remove the system air baffle. 9. Remove the drive cage blank. 10. Install the 8 SFF hot-plug drive cage: a. Install the drive cage in the drive box bay. b. Install the drive cage screws. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 94: Media Device Options

    Connect each power cord to the server. b. Connect each power cord to the power source. 20. Power up the server. Results Results The installation is complete. Media device options Media device options HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 95 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 7. Remove the access panel . HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 96 These screws are included in the RDX docking station option kit. If the option kit does not include screws, use the media device screws on the front panel. 10. Remove the media bay blank. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 97 15. Install the access panel . 16. Do one of the following: Orient the server back to tower mode. Install the server into the rack. 17. Install the front bezel . 18. Connect the power cords: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 98: Optical Drive Option

    If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 99 Slide the optical drive cage out of the server. 11. Remove the optical drive blank: a. Use a plastic spudger to pry one side of the blank. b. Remove the optical drive blank from the optical drive cage. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 100 12. Install the optical drive bracket. 13. Install the optical drive in the optical drive cage: a. Slide the optical drive into the optical drive cage. b. Install the drive bracket screw. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 101 Optical drive cable Front I/O cable 17. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 102 CAUTION: CAUTION: Do not remove and install transceivers more often than is necessary. Doing so can shorten the useful life of the transceiver. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 103: Installing A Transceiver

    M.2 SSD options The server has two M.2 slots on the system board . These slots support NVMe and SATA SSDs in 2280 and 22110 form factors . Install an M.2 SSD option for: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 104: Installing An M.2 Ssd

    If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 6. Remove the access panel . 7. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 105 8. Remove the SSD jack screw from the M.2 location where you intend to install the new SSD. 9. Install the M.2 SSD: a. Insert the SSD into the M.2 slot. b. Position the jack screw on the SSD notch. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 106 Connect each power cord to the server. b. Connect each power cord to the power source. 16. Power up the server. 17. To configure the M.2 SSDs, see the Intel Virtual RAID on CPU for HPE Gen11 User Guide at https://hpe.com/support/VROC-Gen11-UG https://hpe.com/support/VROC-Gen11-UG. Results Results The installation is complete.
  • Page 107: Fan Mode Behavior

    About this task About this task CAUTION: CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static- sensitive devices. To prevent damage, observe antistatic precautions. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 108 Release the fan cable from the cable clamp. b. Remove the screws. Retain the screws. These screws will be used to install the redundant system fan. c. Detach the fan from the chassis. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 109 Tighten the screws on the chassis. 12. To remove the default PCI fan, do the following: a. Release all fan cables from the front cable channel metal tabs. b. Remove the PCI fan cage. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 110 13. To install the redundant PCI fan, do the following: a. Route the fan cable through the fan cage compartment. b. Attach the fan to the fan cage. c. Install the fan screws. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 111 16. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. 17. Install the system air baffle . 18. Install the access panel . 19. Do one of the following: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 112: Memory Option

    Results Results The installation is complete. Memory option Memory option The server has 16 DIMM slots supporting HPE DDR5 SmartMemory (RDIMM) . The arrow points to the front of the server. Subtopics Subtopics HPE SmartMemory speed and population information HPE SmartMemory speed and population information...
  • Page 113: Dimm Installation Guidelines

    HPE SmartMemory speed and population information SmartMemory speed and population information For information about memory speed and server-specific DIMM population rules for HPE servers using 4th Gen Intel Xeon Scalable Processor, see the relevant memory technical paper in: https://www.hpe.com/docs/server-memory https://www.hpe.com/docs/server-memory...
  • Page 114 The DIMM slots are structured to ensure proper installation. If you try to insert a DIMM but it does not fit easily into the slot, you might have positioned it incorrectly. Reverse the orientation of the DIMM and insert it again. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 115 This server supports one riser cage option for standard and high-power expansion card options. The riser cage option supports two PCIe5 x16 riser boards. For more information on the riser slot, see Riser board components . HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 116 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 6. Remove the access panel . 7. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 117 8. Remove the DIMM air baffle: a. Press and hold the release latches on the DIMM air baffle. b. Remove the DIMM air baffle. 9. Remove the riser cage blank. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 118 Tighten the captive screws on the riser cage. 13. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 119 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 120 7. If installed, remove the riser cage. 8. Remove the riser board cover. 9. Remove the secondary riser board screws. Retain the screws. These screws will be used to install the new secondary riser board. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 121 Attach the secondary riser board on the riser cage. b. Install the screws on the riser board. 12. Install the riser board cover. Make sure that the cover is locked on the riser cage with a click sound. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 122: Storage Controller Options

    Storage controller options The server supports the following storage controllers: Intel VROC for HPE Gen11 (Intel VROC)—Provides enterprise-level hybrid RAID support for direct attached SATA and NVMe SSD . HPE MR type-o and type-p Gen11 controllers For more information on drive array and storage controller configuration, see Configuring storage controllers.
  • Page 123 CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static- sensitive devices. To prevent damage, observe antistatic precautions. Procedure Procedure 1. Back up all server data. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 124 8. If you are installing the type-p storage controller in the slot 1, remove the existing rise cage . 9. Install the type-p storage controller: a. Open the riser slot retainer. Retain the screw. This screw will be used to install the type-p storage controller. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 125 Remove the riser slot blank. c. Install the type-p storage controller. Make sure that the type-p storage controller is firmly seated in the riser. Half-height half-length (low-profile) type-p storage controller HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 126 Full-height half-length type-p storage controller 10. Cable the type-p storage controller . 11. To enable the FBWC feature of the storage controller, install an energy pack. 12. Close the riser slot retainer. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 127 To enable the flash-backed write cache (FBWC) feature of a storage controller option, install an energy pack. For more information on the controller caching feature, see the controller QuickSpecs on the Hewlett Packard Enterprise website (https://www.hpe.com/info/qs https://www.hpe.com/info/qs). HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 128 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 6. Remove the access panel . 7. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 129 Default system fan Redundant system fan 9. Remove the OCP slot blank: a. Remove the blank screw. b. Use a plastic spudger to pry the top side of the blank from the chassis. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 130 12. To enable the FBWC feature of the storage controller, install an energy pack. 13. Install the system fan: a. Insert the fan guard pins into the chassis openings. b. Tighten the screws on the chassis. Default system fan HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 131 16. Install the system air baffle . 17. Install the access panel . 18. Do one of the following: Orient the server back to tower mode. Install the server into the rack. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 132 HPE Smart Storage Battery HPE Smart Storage Hybrid Capacitor One energy pack supports multiple devices. After it is installed, the status of the energy pack appears in HPE iLO. For more information, see the iLO user guide: https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6...
  • Page 133: Minimum Firmware Versions

    Make sure that the following components are installed: Compatible storage controller Storage controller backup power cable If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the system meets the minimum firmware requirements . About this task About this task...
  • Page 134 5. Remove the access panel . 6. Remove the system air baffle. 7. If the HPE NS204i-u Boot Device is installed, do the following: a. Disconnect the HPE NS204i-u Boot Device cables from the system board. b. Remove the HPE NS204i-u Boot Device.
  • Page 135 9. Connect the energy pack cable to the system board and secure it in the cable clamp . 10. If removed, install the HPE NS204i-u Boot Device . 11. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps.
  • Page 136: Installing An Expansion Card On The System Board

    CAUTION: CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static- sensitive devices. To prevent damage, observe antistatic precautions. Procedure Procedure HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 137 7. If you are installing the expansion card in the slot 1, remove the existing rise cage . 8. Install the expansion card: a. Open the riser slot retainer. Retain the screw. This screw will be used to install the expansion card. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 138 Remove the riser slot blank. c. Install the expansion card. Make sure that the expansion card is firmly seated in the riser. Half-height half-length (low-profile) expansion card HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 139 Full-height full-length expansion card 9. Connect all necessary internal cabling to the expansion card. For more information on these cabling requirements, see the documentation that ships with the option. 10. Close the riser slot retainer. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 140 About this task About this task CAUTION: CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all PCIe slots have either a riser slot blank or an expansion card installed. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 141 8. To install the expansion card in the riser cage, do the following: a. Remove the riser slot 2 screw. Retain the screw. This screw will be used to install the expansion card. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 142 If you are installing the expansion card in the riser slot 3, remove the riser slot blank from the riser cage. Retain the screw. This screw will be used to install the expansion card. 9. If you are installing the full-height full-length expansion card, open the expansion card holder. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 143 10. Install the expansion card. Make sure that the expansion card is firmly seated in the riser. Half-height half-length (low-profile) expansion card Full-height full-length expansion card HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 144 14. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. 15. Install the system air baffle . 16. Install the access panel . 17. Do one of the following: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 145: Accelerator Options

    Accelerator options This server supports various accelerator options to meet your computational and graphics workload requirements. For a list of supported accelerator models, see the server QuickSpecs on the Hewlett Packard Enterprise website (https://buy.hpe.com/us/en/p/1014705725 https://buy.hpe.com/us/en/p/1014705725). PCIe workload accelerators—These options are PCIe card–based, direct–attach solutions that use solid–state storage technology directly on the PCI bus to boost I/O performance and reduce latency to scale in line with your processing requirements.
  • Page 146 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 147 Retain the screw. This screw will be used to install the PCI air baffle. b. Install the first accelerator in the riser slot 2. Make sure that the accelerator is firmly seated in the riser. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 148 10. If you are installing the second accelerator in the riser slot 3, remove the riser slot screw and blank from the riser cage. Retain the screw. This screw will be used to secure the PCI air baffle. 11. If the L4 Tensor Core graphic accelerator is installed, install the accelerator support option kit: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 149 12. Install the redundant fan option kit . 13. Install the riser cage. 14. Make sure that all the system cables that are routed through the front cable channel are properly secured in the metal cable tabs and cable clamps. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 150 Note the following information about the HPE NS204i-u Boot Device option: The HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage Device (NS204i-u) is a PCIe5 custom form factor module that includes two hot-pluggable 2280 M.2 NVMe SSDs. This boot device enables the deployed OS to be mirrored through a dedicated hardware RAID 1.
  • Page 151 Remove the SSD mounting screw. b. Insert the SSD into the M.2 slot at a 45° angle. c. Carefully press the SSD down to the horizontal position. d. Install the SSD mounting screw. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 152 Make sure that the carrier latch is locked on the boot device cage. Installing the boot device Installing the boot device 4. Back up all server data. 5. Power down the server. 6. Remove all power: HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 153 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 9. Remove the access panel . 10. Remove the system air baffle. 11. Remove the boot device cover. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 154 13. Install the HPE NS204i-u Boot Device cage assembly. Make sure that the HPE NS204i-u Boot Device cage assembly and the release latch are locked on the chassis with the click sound. 14. Connect the boot device signal and power cables to the system board .
  • Page 155 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 156 7. Remove the system fan: a. Release the fan cable from the cable clamp. b. Remove the screws. c. Detach the default system fan from the chassis. Default system fan Redundant system fan HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 157 Slide the adapter into the bay until it clicks into place. Make sure that the adapter is seated firmly in the slot. c. Rotate the locking pin to the close (horizontal) position. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 158 10. Install the system fan: a. Insert the fan guard pins into the chassis openings. b. Tighten the screws on the chassis. Default system fan Redundant system fan HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 159 Subtopics Subtopics Installing the chassis intrusion detection switch Installing the chassis intrusion detection switch HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 160: Installing The Chassis Intrusion Detection Switch

    6. Remove the system air baffle. 7. Install the chassis intrusion detection switch: a. Insert the switch tab into the chassis slot until the switch clicks into place. b. Connect the switch cable. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 161: Serial Port Option

    Install the serial port option to enable communication to physical serial devices. You can also use the serial connection to remotely access the system BIOS and view POST error messages. Subtopics Subtopics Installing a serial port Installing a serial port HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 162 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. 7. If installed, remove the riser cage. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 163 13. Install the access panel . 14. Do one of the following: Orient the server back to tower mode. Install the server into the rack. 15. Connect all peripheral cables to the server. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 164 If the server is in tower mode, place the server on a flat, level surface with the access panel facing up . If the server is in rack mode, remove the server from the rack. 5. Remove the access panel . 6. Remove the system air baffle. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 165 14. Connect all peripheral cables to the server. 15. Connect the power cords: a. Connect each power cord to the server. b. Connect each power cord to the power source. 16. Power up the server. Results Results HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 166: Cabling Guidelines

    Some data cables are prebent. Do not unbend or manipulate the cables. To prevent mechanical damage or depositing oil that is present on your hands, and other contamination, do not touch the ends of the connectors. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 167 Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires of the cable or the pins on the port. If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 168: Cabling Diagrams

    — HPE NS204i-u Boot Device SlimSAS cable P54087-001 HPE NS204i-u Boot Device power cable P54088-001 Miscellaneous component cables Miscellaneous component cables — HPE Smart Storage Battery 96 W, 260 mm cable P01367-B21 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 169: Internal Cabling Management

    Component cabling Component cabling Cable part number Cable part number HPE Smart Storage Hybrid Capacitor, 260 mm cable P02381-B21 Default system fan P49989-001 Default PCI fan Redundant system fan P49986-001 Redundant PCI fan Optical drive SATA-power cable 756914-001 Chassis intrusion detection switch...
  • Page 170: Storage Controller Cabling

    16 SFF hot-plug drive controller cabling 8 LFF non-hot-plug drive controller cabling 8 LFF non-hot-plug drive controller cabling 8 LFF drive: Onboard Intel VROC 8 LFF drive: Onboard Intel VROC SATA cabling SATA cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 171: Lff Hot-Plug Drive Controller Cabling

    Box 2, Port 1 x8 SlimSAS port Blue Box 1, Port 1 Option kit: P54045-B21 8 LFF drive: Slot 14 type-o Gen11 controller cabling 8 LFF drive: Slot 14 type-o Gen11 controller cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 172 Orange Box 2, Port 1 Port 1 Blue Box 1, Port 1 Option kit: P54045-B21 8 LFF drive: Slot 4 type-p Gen11 controller cabling 8 LFF drive: Slot 4 type-p Gen11 controller cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 173: Sff Hot-Plug Drive Controller Cabling

    Option kit: P53484-B21 8 SFF hot-plug drive controller cabling 8 SFF hot-plug drive controller cabling 8 SFF drive: Onboard Intel VROC 8 SFF drive: Onboard Intel VROC SATA cabling SATA cabling Box 1 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 174 Cable part number Cable part number Cable color Cable color From From P60270-001 Orange Box 1, Port 1 x8 SlimSAS port Option kit: P53485-B21 Box 2 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 175 From P60270-001 Orange Box 2, Port 1 x8 SlimSAS port Option kit: P53485-B21 8 SFF drive: Slot 14 type-o Gen11 controller cabling 8 SFF drive: Slot 14 type-o Gen11 controller cabling Box 1 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 176 Cable part number Cable part number Cable color Cable color From From P60270-001 Orange Box 1, Port 1 Port 1 Option kit: P53485-B21 Box 2 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 177 From From P60270-001 Orange Box 2, Port 1 Port 2 Option kit: P53485-B21 8 SFF drive: Slot 4 type-p Gen11 controller cabling 8 SFF drive: Slot 4 type-p Gen11 controller cabling Box 1 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 178 Cable part number Cable part number Cable color Cable color From From P60271-001 Orange Box 1, Port 1 Port 1 Option kit: P55859-B21 Box 2 HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 179 Option kit: P55859-B21 16 SFF hot-plug drive controller cabling 16 SFF hot-plug drive controller cabling 16 SFF drive: Slot 14 type-o Gen11 controller cabling 16 SFF drive: Slot 14 type-o Gen11 controller cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 180 Box 1, Port 1 Port 1 P60270-001 Blue Box 2, Port 1 Port 2 Option kit: P53485-B21 16 SFF drive: Slot 4 type-p Gen11 controller cabling 16 SFF drive: Slot 4 type-p Gen11 controller cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 181 P60271-001 Blue Box 2, Port 1 Port 2 Option kit: P55859-B21 16 SFF drive: Slots 1 and 4 type-p Gen11 controllers cabling 16 SFF drive: Slots 1 and 4 type-p Gen11 controllers cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 182 Box 1, Port 1 Slot 4 Port 1 P60271-001 Blue Box 2, Port 1 Slot 1 Port 1 Option kit: P55859-B21 Hot-plug drive power cabling Hot-plug drive power cabling LFF hot-plug drive power cabling LFF hot-plug drive power cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 183 Cable color From From P60266-001 Orange Box 2 Drive box 2 power connector Blue Box 1 Drive box 1 power connector Option kit: P54045-B21 SFF hot-plug drive power cabling SFF hot-plug drive power cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 184 Cable part number Cable color Cable color From From P60267-001 Orange Box 2 Drive box 2 power connector Blue Box 1 Drive box 1 power connector Option kit: P63974-B21 Energy pack cabling Energy pack cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 185 Cable color Cable color From From P01367-B21 Orange HPE Smart Storage Battery 96 W Energy pack connector P02381-B21 HPE Smart Storage Hybrid Capacitor Storage backup power cabling Storage backup power cabling The exact route of the storage controller backup power cabling will depend on:...
  • Page 186 Cable color From From Orange Slot 14 type-o Gen11 storage controller Slot 14 OROC storage backup power connector Slot 1: Type-p Gen11 storage backup power cabling Slot 1: Type-p Gen11 storage backup power cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 187 Cable color From From Orange Slot 1 type-p Gen11 storage controller Slot 1 storage controller backup power connector Slot 4: Type-p Gen11 storage backup power cabling Slot 4: Type-p Gen11 storage backup power cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 188 Cable color Cable color From From Orange Slot 4 type-p Gen11 storage controller Slot 4 storage controller backup power connector Internal USB RDX docking station cabling Internal USB RDX docking station cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 189 Cable color Cable color From From 876507-002 Orange Internal USB RDX docking station USB 3.2 Gen 1 port P45303-001 Blue Media drive power connector Option kit: P53491-B21 Riser board cabling Riser board cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 190 Power connector for the riser slot Option kit: P53487-B21 This enclosed text (PRIM / SEC) refers to the marker on the riser signal cable connector. HPE NS204i-u Boot Device cabling HPE NS204i-u Boot Device cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 191: Fan Cabling

    Cable part number Cable color Cable color From From P54087-001 Orange HPE NS204i-u Boot Device x8 SlimSAS port P54088-001 Blue NS204i-u power connector Option kit: P61742-B21 Fan cabling Fan cabling Default system and PCI fans HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 192 P49989-001 Orange Default system fan Fan connector 3 Blue Default PCI fan Fan connector 1 Option kit: P49992-B21 This is a black power connector on the system board. Redundant system and PCI fans HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 193 Fan connector 4 Option kit: P49984-B21 This is a white power connector on the system board. This is a black power connector on the system board. Optical drive SATA-power cabling Optical drive SATA-power cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 194 Cable part number Cable part number Cable color Cable color From From 756914-001 Orange Optical drive Optical drive SATA-power connector Option kit: P57364-B21 Chassis intrusion detection switch cabling Chassis intrusion detection switch cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 195: Serial Port Cabling

    Cable part number Cable part number Cable color Cable color From From P47751-001 Orange Chassis intrusion detection Chassis intrusion detection switch switch connector Option kit: P47226-B21 Serial port cabling Serial port cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 196 Cable part number Cable part number Cable color Cable color From From 873747-001 Orange Serial port Serial port connector Option kit: P53489-B21 VGA cabling VGA cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 197: Front I/O Module Cabling

    Cable part number Cable part number Cable color Cable color From From P53987-001 Orange VGA connector Option kit: P49992-B21 Front I/O module cabling Front I/O module cabling HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 198: Configuration Resources

    QuickSpecs (https://buy.hpe.com/us/en/p/1014705725 https://buy.hpe.com/us/en/p/1014705725). Products ordered from HPE Factory Express might have already been configured with some or all the configurations in this chapter. To determine if any additional setup is required, see your HPE Factory Express order. For the most recent changes, feature enhancements, and bug fixes, see the latest product release notes.
  • Page 199: Updating Firmware Or System Rom

    Enable policy-based management of server or server group firmware for distributed server infrastructure https://www.hpe.com/info/com-docs https://www.hpe.com/info/com-docs Monitor server compliance with a configured firmware baseline Receive automatic iLO firmware updates Receive baseline update alerts Configuring the server Configuring the server HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 200 For servers running HPE OneView, do not use another tool, such as iLO, to delete or change certain settings. For more information about using HPE OneView and iLO to manage the same server, see the iLO user guide at https://www.hpe.com/support/ilo6 https://www.hpe.com/support/ilo6.
  • Page 201 Managing the HPE Managing the HPE NS204i-u Boot Device NS204i-u Boot Device For more information on supported features and maintenance information for the HPE NS204i-u Boot Device , see the HPE NS204i-u Boot Device User Guide: https://www.hpe.com/support/NS204-UG https://www.hpe.com/support/NS204-UG Deploying an OS Deploying an OS For a list of supported operating systems, see the HPE Servers Support &...
  • Page 202: Configuring Security

    Configure the server to boot from a SAN HPE Boot from SAN Configuration Guide https://www.hpe.com/info/boot-from-san-config-guide https://www.hpe.com/info/boot-from-san-config-guide Configure the server to boot from a PXE server UEFI System Utilities User Guide for HPE ProLiant Gen11 Servers and HPE Synergy https://www.hpe.com/support/UEFIGen11-UG-en https://www.hpe.com/support/UEFIGen11-UG-en Deploy an OS using iLO virtual media iLO user guide https://www.hpe.com/support/ilo6...
  • Page 203: Nmi Functionality

    To force the OS to initiate the NMI handler and generate a crash dump log, the administrator can use the iLO Generate NMI feature. Troubleshooting resources Troubleshooting resources HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 204: System Battery Replacement

    Integrated Management Log Messages and Troubleshooting Guide for HPE ProLiant Gen11 servers and HPE Synergy provides IML messages and associated troubleshooting information to resolve critical and cautionary IML events.
  • Page 205 6. Remove the system air baffle. 7. If installed, remove the riser cage. 8. If installed, remove the full-height full-length expansion card from the PCIe slot 1, do the following: a. Open the riser slot retainer. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 206 Remove the expansion card. 9. Remove the system battery: a. Use a small flat-bladed, nonconductive tool to press the battery latch. b. Remove the system battery from the socket. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 207 15. Install the access panel . 16. Do one of the following: Orient the server back to tower mode. Install the server into the rack. 17. Connect all peripheral cables to the server. HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 208: Safety, Warranty, And Regulatory Information

    Turkey RoHS material content declaration Ukraine RoHS material content declaration Ukraine RoHS material content declaration Notices for Eurasian Economic Union Notices for Eurasian Economic Union Manufacturer and Local Representative Information Manufacturer and Local Representative Information HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 209: Turkey Rohs Material Content Declaration

    Фараби даңғ ылы, 77/7, Телефон/факс: +7 727 355 35 50 Manufacturing date: Manufacturing date: The manufacturing date is defined by the serial number. If you need help identifying the manufacturing date, contact tre@hpe.com tre@hpe.com. Turkey RoHS material content declaration Turkey RoHS material content declaration Türkiye Cumhuriyeti: AEEE Yönetmeliğine Uygundur...
  • Page 210: Environmental Specifications

    40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum of 3,050 m (10,000 ft). The approved hardware configurations for this system are listed in the Extended Ambient Temperature Guidelines for Gen11 HPE ProLiant servers: https://www.hpe.com/support/ASHRAEGen11...
  • Page 211: Power Supply Specifications

    Subtopics Subtopics HPE 500 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 500 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply...
  • Page 212 500 W at 100 VAC to 240 VAC input 500 W at 240 VDC input for China only HPE 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply 800 W Flex Slot Platinum Hot-plug Low Halogen Power Supply HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 213 800 W at 100 VAC to 240 VAC input 800 W at 240 VDC input for China only HPE 1000 W Flex Slot Titanium Hot-plug Power Supply 1000 W Flex Slot Titanium Hot-plug Power Supply HPE ProLiant ML110 Gen11 Server User Guide...
  • Page 214 Maximum peak power 1000 W at 100 VAC to 127 VAC 1000 W at 200 VAC to 240 VAC HPE 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply 1600 W Flex Slot Platinum Hot-plug Low Halogen Power Supply Specification...
  • Page 215: Support And Other Resources

    Product white papers and analyst reports https://www.hpe.com/us/en/resource-library https://www.hpe.com/us/en/resource-library For additional websites, see Support and other resources. Product websites Product websites HPE ProLiant ML110 Gen11 Server product page https://buy.hpe.com/us/en/p/1014705725 https://buy.hpe.com/us/en/p/1014705725 HPE ProLiant ML110 Gen11 Server user documents https://www.hpe.com/info/ml110gen11-docs https://www.hpe.com/info/ml110gen11-docs Support and other resources...
  • Page 216: Accessing Updates

    IMPORTANT: IMPORTANT: Access to some updates might require product entitlement when accessed through the Hewlett Packard Enterprise Support Center. You must have an HPE Account set up with relevant entitlements. Customer self repair Customer self repair Hewlett Packard Enterprise customer self repair (CSR) programs allow you to repair your product. If a CSR part needs to be replaced, it will be shipped directly to you so that you can install it at your convenience.
  • Page 217: Documentation Feedback

    Feedback button and icons (at the bottom of an opened document) on the Hewlett Packard Enterprise Support Center portal (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc) to send any errors, suggestions, or comments. This process captures all document information. HPE ProLiant ML110 Gen11 Server User Guide...