Smart Storage Battery Option; Installing The Smart Storage Battery - HPE ProLiant ML350 Gen10 User Manual

Hide thumbs Also See for ProLiant ML350 Gen10:
Table of Contents

Advertisement

Procedure
1. Remove the protective film from the cushion.
2. Align one end of the cushion to the edge of the heatsink, and then press the cushion down to attach it.
3. Install the cover over the connector.

Smart Storage Battery option

The Smart Storage Battery is a centralized backup source and is required to back up the write cache content
onto flash memory on the Smart Array P-class Gen10 controllers in case of an unplanned server power loss.
In this server, the 96 W, 260 mm battery supports up to 24 devices.
After the battery is installed, it might take up to two hours to charge. Controller features requiring backup
power are not enabled until the battery is capable of providing the backup power.

Installing the Smart Storage Battery

Prerequisites
Before you perform this procedure:
Make sure that a Smart Array P-class Gen10 standup controller is installed.
Make sure you have the following items available:
The Smart Array cache backup power cable that ships with the standup controller
Smart Storage Battery option
Procedure
1.
Remove the front bezel on page 39.
2.
Power down the server on page 38.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
Smart Storage Battery option
121