Drive Cage Options - HPE ProLiant ML110 Gen11 User Manual

Table of Contents

Advertisement

Results
Results
The installation is complete.

Drive cage options

Drive cage options
The server supports the following drive cage options:
4 LFF non-hot-plug drive cage
4 LFF hot-plug drive cage
8 SFF hot-plug drive cage
When install the drive cage, always populate from the box 1.
This server supports one mixed hot-plug drive cage configuration—4 LFF drive cage in the box 1 with 8 SFF drive cage in the box 2.
Mixing non-hot-plug and hot-plug drive cage in this server is not supported.
Subtopics
Subtopics
Installing the 4 LFF non-hot-plug drive cage option
Installing the 4 LFF non-hot-plug drive cage option
Installing the 4 LFF hot-plug drive cage option
Installing the 4 LFF hot-plug drive cage option
Installing the 8 SFF hot-plug drive cage option
Installing the 8 SFF hot-plug drive cage option
Installing the 4 LFF non-hot-plug drive cage option
Installing the 4 LFF non-hot-plug drive cage option
Prerequisites
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
About this task
About this task
CAUTION:
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
CAUTION: A discharge of static electricity from a finger or other conductor might damage system boards or other static-
CAUTION:
sensitive devices. To prevent damage, observe antistatic precautions.
Procedure
Procedure
1. Back up all server data.
2. Power down the server.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. If installed, remove the front bezel .
6. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
HPE ProLiant ML110 Gen11 Server User Guide