Remove the fan cage

Procedure
1. Remove the front bezel on page 39.
2. Power down the server on page 38.
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripherals cables from the server.
5. If installed, unlock and remove the security padlock and/or the Kensington security lock.
For more information, see the lock documentation.
6. Do one of the following:
Server in tower mode: Position the tower server for hardware configuration on page 41.
Server in rack mode: Extend the server from the rack on page 43.
7. Remove the access panel on page 48.
8. Remove the fan cage:
a. Open the blue latches to a 90° angle.
b. Use the latches to pull up the fan cage out of the chassis.
54
Remove the fan cage