Specifications
Environmental specifications
Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,050 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every
175 m (1.8°F per every 574 ft) above 900 m (2,953 ft) to a maximum of 3,050 m (10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410
ft) above 900 m (2,953 ft) to a maximum of 3,050 m (10,000 ft).
The approved hardware configurations for this system are listed on the Hewlett Packard Enterprise website (http://
www.hpe.com/servers/ASHRAE).
Mechanical specifications
Specification
Height
Depth
Width
Weight (approximate values)
24-bay LFF drive models
Without the four-bay rear LFF drive cage option, minimum
Without the four-bay rear LFF drive cage option, maximum
170
Specifications
1
Value
—
10°C to 35°C (50°F to 95°F)
-30°C to 60°C (-22°F to 140°F)
—
8% to 90%. 28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
87.50 mm (3.44 in)
825.50 mm (32.50 in)
448.0 mm (17.63 in)
—
—
22.34 kg (49.25 lb)
39.74 kg (87.63 lb)
Table Continued